Computer Hardware User Manual
•FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
•SeeChapter7“Partslisting,RS210Types6531,6532,6533,and6534”onpage175todeterminewhich
componentsarecustomerreplaceableunits(CRU)andwhichcomponentsareeldreplaceableunits(FRU).
•Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlyby
atrainedservicetechnician.
Array%1isincriticalcondition.(%1=
CIM_ComputerSystem.ElementName)
Error
AnarrayisinCritical
state.(Sensor=Driven
Status)(n=harddiskdrive
number)
Replacetheharddiskdrivethatis
indicatedbyalitstatusLED.
Array%1hasfailed.(%1=
CIM_ComputerSystem.ElementName)
ErrorAnarrayisinFailed
state.(Sensor=Driven
Status)(n=harddiskdrive
number)
Replacetheharddiskdrivethatis
indicatedbyalitstatusLED.
Memoryuncorrectableerrordetected
forDIMMAllDIMMsonMemory
SubsystemAllDIMMs.
ErrorAmemoryuncorrectable
errorhasoccurred.
1.IftheserverfailedthePOST
memorytest,reseatthe
DIMMs.
2.ReplaceanyDIMMthatis
indicatedbyaliterrorLED.
Note:Youdonothaveto
replaceDIMMsbypairs.
3.RuntheSetuputilitytoenable
alltheDIMMs.
4.RuntheDSAmemorytest.
MemoryLoggingLimitReached
forDIMMAllDIMMsonMemory
SubsystemAllDIMMs.
ErrorThememorylogginglimit
hasbeenreached.
1.Updatetheserverrmwareto
thelatestlevel.
Important:Somecluster
solutionsrequirespeciccode
levelsorcoordinatedcode
updates.Ifthedeviceispart
ofaclustersolution,verify
thatthelatestlevelofcode
issupportedforthecluster
solutionbeforeyouupdatethe
code.
2.ReseattheDIMMsandrunthe
DSAmemorytest.
3.ReplaceanyDIMMthatis
indicatedbyaliterrorLED.
MemoryDIMMCongurationError
forAllDIMMsonMemorySubsystem
AllDIMMs.
Error
ADIMMcongurationerror
hasoccurred.
MakesurethatDIMMsare
installedinthecorrectsequence
andhavethesamesize,type,
speed,andtechnology.
Chapter4.Diagnostics35