Computer Hardware User Manual

FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
SeeChapter7“Partslisting,RS210Types6531,6532,6533,and6534”onpage175todeterminewhich
componentsarecustomerreplaceableunits(CRU)andwhichcomponentsareeldreplaceableunits(FRU).
Ifanactionstepisprecededby“(Trainedservicetechnicianonly),thatstepmustbeperformedonlyby
atrainedservicetechnician.
SensorCPUnOverTemphas
transitionedtonon-recoverable.(n=
microprocessornumber)
ErrorAsensorhaschangedto
Nonrecoverablestate.
1.Makesurethatthefansare
operating,thatthereareno
obstructionstotheairow,that
theairbafeisinplaceand
correctlyinstalled,andthat
theservercoverisinstalled
andcompletelyclosed.
2.Makesurethattheheat
sinkformicroprocessornis
installedcorrectly.
3.(Trainedservicetechnician
only)Replacemicroprocessor
n.
(n=microprocessornumber)
Abustimeouthasoccurred
onsystem%1.(%1=
CIM_ComputerSystem.ElementName)
ErrorAbustimeouthasoccurred.
1.Removetheadapterfromthe
PCIslotthatisindicatedbya
litLED.
2.Replacetheextendercard.
3.RemoveallPCIadapters.
4.(Trainedservicetechnicians
only)Replacethesystem
board.
TheSystem%1encountered
aPOSTError.(%1=
CIM_ComputerSystem.ElementName)
Error
APOSTerrorhas
occurred.(Sensor=ABR
Status)
1.Recovertheserverrmware
fromthebackuppage(see
“Recoveringtheserver
rmware”onpage100
).
2.Updatetheserverrmwareto
thelatestlevel.
Important:Somecluster
solutionsrequirespeciccode
levelsorcoordinatedcode
updates.Ifthedeviceispart
ofaclustersolution,verify
thatthelatestlevelofcode
issupportedforthecluster
solutionbeforeyouupdatethe
code.
Chapter4.Diagnostics31