Computer Hardware User Manual
•FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
•SeeChapter7“Partslisting,RS210Types6531,6532,6533,and6534”onpage175todeterminewhich
componentsarecustomerreplaceableunits(CRU)andwhichcomponentsareeldreplaceableunits(FRU).
•Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlyby
atrainedservicetechnician.
•GototheLenovosupportWebsiteathttp://www.lenovo.com/supporttocheckfortechnicalinformation,
hints,tips,andnewdevicedriversortosubmitarequestforinformation.
ErrorcodeDescriptionAction
0051003UncorrectableDIMMerror
1.IftheserverfailedthePOSTmemorytest,reseat
theDIMMs.
2.RemoveandreplaceanyDIMMforwhichthe
associatederrorLEDislit(see“Removinga
memorymodule”onpage125and“Installinga
memorymodule”onpage125).
3.RuntheSetuputilitytoenablealltheDIMMs.
4.RuntheDSAPrebootmemorytest(see“Running
thediagnosticprograms”onpage65
).
0051006DIMMmismatchdetectedMakesurethattheDIMMsmatchandareinstalled
inthecorrectsequence(see“Installingamemory
module”onpage125
).
0051009Nomemorydetected.1.MakesurethattheservercontainsDIMMs.
2.ReseattheDIMMs.
3.InstallDIMMsinthecorrectsequence(see
“Installingamemorymodule”onpage125).
005100ANousablememorydetected.1.MakesurethattheservercontainsDIMMs.
2.ReseattheDIMMs.
3.InstallDIMMsinthecorrectsequence(see
“Installingamemorymodule”onpage125
).
4.ClearCMOSmemorytore-enableallthememory
connectors(see“System-boardswitchesand
jumpers”onpage111).
0058001PFAthresholdexceeded
1.Updatetheserverrmwaretothelatestlevel(see
“Updatingthermware”onpage211).
2.ReseattheDIMMsandrunthememorytest(see
“Runningthediagnosticprograms”onpage65
).
3.ReplacethefailingDIMM,whichisindicatedbya
litLEDonthesystemboard.
Chapter4.Diagnostics21