Computer Hardware User Manual

Table5.DSAPrebootmessages(continued)
FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
SeeChapter7“Partslisting,RS210Types6531,6532,6533,and6534”onpage175
todeterminewhich
componentsarecustomerreplaceableunits(CRU)andwhichcomponentsareeldreplaceableunits(FRU).
Ifanactionstepisprecededby“(Trainedservicetechnicianonly),thatstepmustbeperformedonlyby
aTrainedservicetechnician.
GototheLenovosupportWebsiteathttp://www.lenovo.com/supporttocheckfortechnicalinformation,
hints,tips,andnewdevicedriversortosubmitarequestforinformation.
Message
numberComponentTestStateDescriptionAction
201-810-xxxMemoryMemory
Test
AbortedTest
stopped:
unknown
error
codexxx
receivedin
COMMONEXIT
procedure.
1.Turnoffandrestartthesystem.
2.Runthetestagain.
3.MakesurethattheDSAcodeisatthelatest
level.ForthelatestlevelofDSAcode,goto
http://www.lenovo.com/support.
4.Makesurethattheserverrmwareisat
thelatestlevel.Theinstalledrmware
levelisshownintheDSAeventloginthe
Firmware/VPDsectionforthiscomponent.For
moreinformation,see“Updatingthermware”
onpage211.
5.Runthetestagain.
6.Ifthefailureremains,gototheLenovoWebsite
formoretroubleshootinginformationat
http://www.lenovo.com/support..
201-901-xxxMemoryMemory
Test
Failed
Testfailure:
single-bit
error,failing
DIMMz.
1.Turnoffthesystemanddisconnectitfromthe
powersource.
2.ReseatDIMMz.
3.Reconnectthesystemtopowerandturnon
thesystem.
4.MakesurethattheDSAcodeisatthelatest
level.ForthelatestlevelofDSAcode,goto
http://www.lenovo.com/support.
5.Makesurethattheserverrmwareisat
thelatestlevel.Theinstalledrmware
levelisshownintheDSAeventloginthe
Firmware/VPDsectionforthiscomponent.For
moreinformation,see“Updatingthermware”
onpage211
.
6.Runthetestagain.
7.ReplacethefailingDIMMs.
8.Re-enableallmemoryintheSetuputility(see
“UsingtheSetupUtility”onpage197
).
9.Runthetestagain.
10.ReplacethefailingDIMM.
11.Ifthefailureremains,gototheLenovoWebsite
formoretroubleshootinginformationat
http://www.lenovo.com/support..
Chapter4.Diagnostics89