Computer Hardware User Manual
•FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
•SeeChapter7“Partslisting,RS210Types6531,6532,6533,and6534”onpage175todeterminewhich
componentsarecustomerreplaceableunits(CRU)andwhichcomponentsareeldreplaceableunits(FRU).
•Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlyby
aTrainedservicetechnician.
•GototheLenovosupportWebsiteathttp://www.lenovo.com/supporttocheckfortechnicalinformation,
hints,tips,andnewdevicedriversortosubmitarequestforinformation.
SymptomAction
Anewlyinstalledharddisk
driveisnotrecognized.
1.ObservetheassociatedamberharddiskdrivestatusLED.IftheLEDislit,it
indicatesadrivefault.
2.IftheLEDislit,removethedrivefromthebay,wait45seconds,andreinsert
thedrive,makingsurethatthedriveassemblyconnectstotheharddiskdrive
backplane.
3.ObservetheassociatedgreenharddiskdriveactivityLEDandtheamberstatus
LED:
•IfthegreenactivityLEDisashingandtheamberstatusLEDisnotlit,the
driveisrecognizedbythecontrollerandisworkingcorrectly.RuntheDSA
harddiskdrivetesttodeterminewhetherthedriveisdetected.
•IfthegreenactivityLEDisashingandtheamberstatusLEDisashing
slowly,thedriveisrecognizedbythecontrollerandisrebuilding.
•IfneitherLEDislitorashing,checktheharddiskdrivebackplane(goto
step4onpage49
).
•IfthegreenactivityLEDisashingandtheamberstatusLEDislit,replacethe
drive.IftheactivityoftheLEDsremainsthesame,gotostep4onpage49.If
theactivityoftheLEDschanges,returntostep1onpage49.
4.Makesurethattheharddiskdrivebackplaneiscorrectlyseated.Whenitis
correctlyseated,thedriveassembliescorrectlyconnecttothebackplanewithout
bowingorcausingmovementofthebackplane.
5.Reseatthebackplanepowercableandrepeatsteps1onpage49through3
onpage49
.
6.Reseatthebackplanesignalcableandrepeatsteps1onpage49through3
onpage49.
7.Suspectthebackplanesignalcableorthebackplane:
•Replacetheaffectedbackplanesignalcable.
•Replacetheaffectedbackplane.
8.RunthediagnostictestsfortheSAS/SATAcontrollerandharddiskdrives(see
“Diagnostictools”onpage17
).
•Ifthecontrollerpassesthetestbutthedrivesarenotrecognized,replacethe
backplanesignalcableandrunthetestsagain.
•Replacethebackplane.
•Ifthecontrollerfailsthetest,disconnectthebackplanesignalcablefrom
thecontrollerandrunthetestsagain.
•Ifthecontrollerfailsthetest,replacethecontroller.
9.See“Problemdeterminationtips”onpage104..
Multipleharddiskdrivesfail.
Makesurethattheharddiskdrive,SAS/SATARAIDcontroller,andserverdevice
driversandrmwareareatthelatestlevel.
Important:Someclustersolutionsrequirespeciccodelevelsorcoordinatedcode
updates.Ifthedeviceispartofaclustersolution,verifythatthelatestlevelofcode
issupportedfortheclustersolutionbeforeyouupdatethecode.
Chapter4.Diagnostics49