Computer Hardware User Manual
•FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
•SeeChapter7“Partslisting,RS210Types6531,6532,6533,and6534”onpage175todeterminewhich
componentsarecustomerreplaceableunits(CRU)andwhichcomponentsareeldreplaceableunits(FRU).
•Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlyby
atrainedservicetechnician.
AUncorrectableBusErrorhas
occurredonsystem%1.(%1=
CIM_ComputerSystem.ElementName)
ErrorAbusuncorrectableerror
hasoccurred.(Sensor=
CriticalIntCPU)
1.Checkthesystem-eventlog.
2.Checkthemicroprocessor
errorLEDs.
3.(Trainedservicetechnician
only)Replacemicroprocessor
.
4.Checkforaserverrmware
update.
Important:Somecluster
solutionsrequirespeciccode
levelsorcoordinatedcode
updates.Ifthedeviceispart
ofaclustersolution,verify
thatthelatestlevelofcode
issupportedforthecluster
solutionbeforeyouupdatethe
code.
5.(Trainedservicetechnician
only)Replacethesystem
board.
AUncorrectableBusErrorhas
occurredonsystem%1.(%1=
CIM_ComputerSystem.ElementName)
ErrorAbusuncorrectableerror
hasoccurred.(Sensor=
CriticalIntDIM)
1.Checkthesystem-eventlog.
2.ChecktheDIMMerrorLEDs.
3.RemovethefailingDIMMfrom
thesystemboard.
4.Checkforaserverrmware
update.
Important:Somecluster
solutionsrequirespeciccode
levelsorcoordinatedcode
updates.Ifthedeviceispart
ofaclustersolution,verify
thatthelatestlevelofcode
issupportedforthecluster
solutionbeforeyouupdatethe
code.
5.Makesurethattheinstalled
DIMMsaresupportedand
conguredcorrectly.
6.(Trainedservicetechnician
only)Replacethesystem
board.
Chapter4.Diagnostics33