Computer Hardware User Manual

Installingthesystemboard
Note:Whenyoureassemblethecomponentsintheserver,besuretorouteallcablescarefullysothatthey
arenotexposedtoexcessivepressure.
Notes:
1.Whenyoureassemblethecomponentsintheserver,besuretorouteallcablescarefullysothatthey
arenotexposedtoexcessivepressure.
2.Whenyoureplacethesystemboard,youmusteitherupdatetheserverwiththelatestrmwareorrestore
thepre-existingrmwarethatthecustomerprovidesonadisketteorCDimage.Makesurethatyou
havethelatestrmwareoracopyofthepre-existingrmwarebeforeyouproceed.See“Updatingthe
rmware”onpage211
“UpdatingtheUniversalUniqueIdentier(UUID)”onpage168“Updatingthe
DMI/SMBIOSdata”onpage170formoreinformation.
Important:Someclustersolutionsrequirespeciccodelevelsorcoordinatedcodeupdates.Ifthedeviceis
partofaclustersolution,verifythatthelatestlevelofcodeissupportedfortheclustersolutionbeforeyou
updatethecode
Toinstallthesystemboard,completethefollowingsteps:
1.Readthesafetyinformationin“ImportantSafetyInformation”onpage1and“Guidelinesfortrained
servicetechnicians”onpage115.
2.Alignthesystemboardwiththechassis,andreplacethescrewsthatsecurethesystemboard.
3.Reinstallthemicroprocessorandheatsink(see“Installingthemicroprocessoronpage141).
4.ReinstalltheDIMMs(see“Installingamemorymodule”onpage125).
5.ReinstalltheDIMMairbafe(see“RemovingandinstallingtheDIMMairbafe”onpage121).
6.Ifnecessary,reinstallServeRAID-BR10ilSAS/SATAcontroller(see“InstallinganIBMServeRAID-BR10il
SAS/SATAcontroller”onpage159).
7.ReinstallthePCIriser-cardassembliesandPCIcards,ifanywereinstalled(see“Installingtheriser-card
assembly”onpage157and“InstallingaPCIcard”onpage132).
8.Reinstallthevirtualmediakey(see“Replacingthevirtualmediakey”onpage165).
9.Reinstallthehypervisorashdevice(see“InstallingaUSBembeddedhypervisorashdevice”onpage
134).
10.Reconnectallcablestothesystemboardthatweredisconnected.
11.Installthecover(see“Removingandinstallingthecover”onpage119).
12.Slidetheserverintotherack.
13.Reconnectthepowercordsandanycablesthatyouremoved.
14.Turnontheperipheraldevicesandtheserver.
Important:Performthefollowingupdates:
EitherupdatetheserverwiththelatestRAIDrmwareorrestorethepre-existingrmwarefromadiskette
orCDimage.
UpdatetheUUID(see“UpdatingtheUniversalUniqueIdentier(UUID)”onpage168.
UpdatetheDMI/SMBIOS(see“UpdatingtheDMI/SMBIOSdata”onpage170
).
Replacingthepowersupply
Thisprocedureisusedwhenreplacingadefectivepowersupply.
Whenyouremoveorinstallthepowersupply,observethefollowingprecautions.
Chapter6.ReplacingFRUs145