Submittal Sheet

HC11 / HC16 Media Air Cleaners / Page 5
MATCH-UPS - FILTER CABINET WITH FURNACE / AIR HANDLER
ALSO SEE ILLUSTRATIONS ON NEXT PAGE FOR ADDITIONAL DETAILS
Furnaces
Filter Cabinet
Comment
HCC14-23 HCC16-28 HCC20-28
“A” Width Furnace with Side Return Air No duct transition required.
“A” Width Furnace with Bottom Return Air 28-1/2 x 3 in. side seal strip or duct transition needed.
“B” Width Furnace with Side Return Air No duct transition required.
“B” Width Furnace with Bottom Return Air No duct transition required.
“C” Width Furnace with Side Return Air
(up to 4 ton)
No duct transition required,
for high system static application use HCC20-28.
“C” Width Furnace with Side Return Air
(5 ton)
Option 1 - No duct transition required, use Return Air
Base (98M58).
Option 2 - Overcut top edge of side return opening by 1
in. to make opening 15 x 23 in. (H x W).
“C” Width Furnace with Bottom Return Air No duct transition required.
“D” Width Furnace with Side Return Air
Option 1 - No duct transition required, use Return Air
Base (98M59).
Option 2 - Overcut top edge of side return opening by 1
in. to make opening 15 x 23 in. (H x W).
“D” Width Furnace with Bottom Return Air 28-1/2 x 3 1/2 in. side seal strip or duct transition needed.
Air Handlers HCC14-23 HCC16-28 HCC20-28 Comment
Air Handler (W x D) - 15 x 22 in.
CBX25UH(V)-018
Duct transition required.
Air Handler (W x D) - 18-1/2 x 22 in.
CBX25UH(V)-024-030
22 x 2 in. side seal strip or duct transition needed.
Air Handler (W x D) - 21-7/8 x 22 in.
CBX25UH(V)-036
No duct transition required.
Air Handler (W x D) - 21-7/8 x 26 in.
CBX25UH(V)-042-048-060
No duct transition required.
Air Handler (W x D) - 16-1/4 x 20-5/8 in.
CBX32M-018/024
Duct transition required.
Air Handler (W x D) - 21-1/4 x 20-5/8 in.
CBA27UH-018
CBA27UH-024
CBA38MV-018/024
CBX32M-030
No duct transition required.
Air Handler (W x D) - 21-1/4 x 22-5/8 in.
CBA27UH-030
CBA27UH-036
CBA38MV-030-036
CBX32M-036-042
No duct transition required.
Air Handler (W x D) - 21-1/4 x 24-5/8 in.
CBA27UH-042
CBA27UH-048
CBA27UH-060
CBA38MV-042-048-060
CBX32M-048-060
21 x 3 in. side seal strip or duct transition needed.
Hot Water Air Handlers HCC14-23 HCC16-28 HCC20-28 Comment
“B” Width CBWMV with Side Return Air No duct transition required.
“B” Width CBWMV with Bottom Return Air No duct transition required.
“C” Width CBWMV with Side Return Air
(up to 4 ton)
No duct transition required,
for high system static application use HCC20-28.
“C” Width CBWMV with Side Return Air
(5 ton)
Option 1 - No duct transition required, use Return Air
Base (98M58).
Option 2 - Overcut top edge of side return opening by 1
in. to make opening 15 x 23 in. (H x W).
“C” Width CBWMV with Bottom Return Air No duct transition required.