Submittal Sheet

HC11 / HC16 Media Air Cleaners / Page 2
FEATURES
APPLICATIONS
NOTE - Cabinet and Filter must be ordered separately.
MERV 11 and MERV 16 lters (Minimum Efciency
Reporting Value based on ASHRAE 52.2).
High performance ltration with a narrow 7 in. cabinet.
Pleated lter design allows maximum air ow and
ltration efciency.
Multi-position cabinet is available for installation
on the return air opening of gas, oil or electric
forced, warm air furnaces and air handlers with
cooling applications up to 5 tons. The unit can
be installed in upflow, downflow or horizontal unit
applications.
Silent operation, requires no electrical component
service, and generates no ozone.
Constant blower operation will achieve the best air
cleaning results.
No duct transition needed for most furnace
applications. See Match-Up Table for additional
details on page 5.
WARRANTY
HCC cabinet and HCXF reusable lter box has a ve
year limited warranty in residential applications, one
year in non-residential applications.
Filter media is not covered.
Refer to Healthy Climate Equipment Limited Warranty
certicate included with cabinet for specic details.
INSTALLATION CONSIDERATIONS
A 25 in. clearance in front of the air cleaner is required
to allow removal of lter media.
Due to the ue location on downow furnaces, the front
of the air cleaner must be installed to the side or rear
of the furnace cabinet. If installed in a conned space,
service clearance may be restricted.
If an atomizing spray type humidier is also used, it
must be installed downstream from the air cleaner.
If a UV germicidal light is used in the system, maintain
a minimum distance of 6 ft. from the air cleaner if they
are in direct line of sight to one another. Maintain a
minimum of 3 ft. if using a 90° bend or turn in the duct.
CABINET
Constructed of pre-painted cold rolled steel.
Cabinet will withstand 400 lbs. static weight, enough to
support the weight of a typical furnace and indoor coil or
air handler.
Tool-less access door allows quick and easy
replacement of lter media.
Mounts in any position. Air ow direction through the
cabinet can be changed by re–positioning the lter.
Arrows on lter indicate air ow direction.
Cabinet is shipped compact and requires minimum eld
assembly. No tools required.
FILTER MEDIA
Carbon Clean 16
®
(MERV 16) Box Filters
Disposable, pleated MERV 16 lters (Minimum
Efciency Reporting Value based on ASHRAE 52.2).
50% rst-pass reduction of ozone.
Carbon coated ber matrix reduces odors.
Hospital inpatient care/general surgery level ltration.
Removes over 95% of E1 (sub-micron) particles down
to 0.3-1 microns.
Removes over 99% of E2 particles down to 1-3 microns.
Removes over 90% of ultra-ne particles down to 0.01
micron, including viruses and bacteria.
Double-wall beverage board frame for rigid construction.
Filter is certied to UL 900 standard for ammability only
and Class 2 in accordance with ULC S111.
MERV 11 Box Filters
Disposable, pleated MERV 11 lters (Minimum
Efciency Reporting Value based on ASHRAE 52.2).
Dust mites, pollen, mold spores, pet dander and other
contaminants are captured by the lter.
Double-wall beverage board frame for rigid construction.
Recommended replacement of the media depends on a
variety of factors, see Specications table.
Filter is certied to UL 900 standard for ammability only
and Class 2 in accordance with ULC S111.
Expandable Filter Kits
Disposable, pleated MERV 11 or MERV 16 lters
(Minimum Efciency Reporting Value based on
ASHRAE 52.2).
Dust mites, pollen, mold spores, pet dander and other
contaminants are captured by the lter.
Double-wall beverage board frame for rigid construction.
Recommended replacement of the media depends on a
variety of factors, see Specications table.
Filter is certied to UL 900 standard for ammability only
and Class 2 in accordance with ULC S111.
Filter kit is shipped compact for eld assembly.
All kits consist of an expandable lter media and
reusable lter box.
MERV 16 kits also include reusable lter spacers.
CONTENTS
Dimensions ................................................................. 3
Features....................................................................... 2
Filter Air Resistance - HCF .......................................... 4
Filter Air Resistance - HCXF ........................................ 4
Maintenance Supplies ................................................. 3
Match-Ups - Filter Cabinet With Furnace / Air Handler 5
Minimum Filter Efciency ............................................. 4
Model Number Identication ........................................ 1