1. Use the included wall template along with a
eld-provided level tool for proper horizontal
alignment on the wall before marking the
mounting holes.
2. Cut or drill 3/8" hole in wall for R and C wiring.
Insure wiring hole is positioned properly
in relationship to smart device terminals
location.
3/8” (10 mm)
Diameter Hole
where wires feed
into terminal C and R
on IAQ Monitor.
Level Tool
3. Pull about three inches (75mm) of thermostat
wire (18 - 24 AWG) through the opening and
remove the outer thermostat wire jacket.
IMPORTANT
Seal wire hole in wall to prevent internal wall
containments from aecting sensors.
4. Strip 1/4” (6 mm) insulation from end of each
wire.
5. The other end of the wiring should be routed
behind the wall to the thermostat sub-
base location. Use the provided three-wire
splice connectors to connect to the R and C
terminals (see "Terminal Designations and
Wiring Recommendations" on page 11 for
wiring details).
6. Using the provided wall template, drill 3/16”
(5 mm) holes at marked locations on the wall
for anchors.
Drill Holes
Align template as illustrated below for
proper placement alignment of the SAQM.
7. Then insert wall anchors into holes until ush
with the wall.