CARE AND OPERATION INSTRUCTIONS EDV Direct-Vent Gas Fireplaces P/N 875021M Rev. K 01/2011 MODELS This manual is part of a set of two supporting this product. Refer to P/N 850017M for Installation Instructions. Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 875021CF. Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety and Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thank you for your purchase. We appreciate your business! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information. Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace. • FREE SAFETY GUARD OFFER • The Lennox® SAFETY GUARD protects against severe burns and injuries by preventing direct contact with the front glass surface of your fireplace.
[FRENCH] La sécurité et votre foyer Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTRÊMEMENT CHAUDES ! Afin d'éviter de vous brûler gravement ou de vous blesser, installez une grille ou une barrière physique pour empêcher tout contact direct avec la vitre. Pour commander un PANNEAU DE PROTECTION Lennox® GRATUIT pour votre foyer, consultez les détails dans la partie gauche.
Important Safety Information L'information de sûreté importante 1. WARNING: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person . 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué ou brisé. Confiez le remplacement du panneau à un technicien agréé 2. Do not use this appliance if any part has been under water.
HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGS Attaching Safety-in-Operation Warnings Apposition des mises en garde relatives à la sécurité d’utilisation Colocación de advertencias de seguridad en operación Your fireplace has been furnished with safety instruction labels that are to be affixed to the operation and control point of the fireplace.
General Information The fireplace models covered in this manual are direct-vent sealed combustion gas fireplace heaters designed for residential application. These direct-vent appliances operate with the combustion chamber completely isolated from the indoor environment. All air for combustion is brought in from the outside and exhaust gases are vented through the same direct-vent, co-axial (intake/exhaust) vent system. The Millivolt appliances have a millivolt gas control valve with piezo ignition system.
BTU Input These fireplaces are designed as supplemental heaters. Therefore, it is advisable to have an alternate primary heat source when installed in a dwelling. Millivolt Models - The millivolt appliances are manually controlled and feature a spark igniter (piezo) that allows the appliance's pilot gas to be lit without the use of matches or batteries. This system provides continued service in the event of a power outage.
Operation and care of your appliance WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
Variable Flame Height Adjustment Inlet Pressure Port Manifold Pressure Port 1. All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings, alternately, while the appliance is in operation. IN OUT TPTH TP HI TH LO W OFF i t P IL O T ON P IL OT SIT Millivolt Gas Valve Main Gas Control Knob Note: The piezo ignitor is located on the modesty panel - refer to Figure 1.
MAINTENANCE (See Maintenance Schedule, Page 23) Refer to the maintenance schedule for maintenance tasks, procedures, periodicity and by whom they should be performed. Always verify proper operation of the appliance after servicing. WARNING Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance. CAUTION: Wear gloves and safety glasses for protection while doing required maintenance. Verify proper operation after servicing.
Front Glass Enclosure Panel, Removal and Installation WARNING • Do not attempt to substitute the materials used on this door, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage – Do not scratch or handle roughly while reinstalling the glass door frame. • The glass door(s) of this appliance must only be replaced as a complete unit as provided by the manufacturer. Do not attempt to replace broken, cracked or chipped glass separately.
INSTALL VOLCANIC STONE, GLOWING EMBERS AND LOGS Glowing Embers NOTE: Turn off all electricity to the appliance before you install volcanic stone, embers and logs. DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out. Step 1. Remove the appliance front door (see Removing Glass Encloslure panel on page 11. Step 2.
EDV3530 Log Placement Log Number 1 2 1 2 3 4 5 6 Description Part Number Log, Rear Log, Diagonal/Left Log, Diagonal/Right Log, Front/Left Log, Top/Right Log, Front/Center 55M06 55M07 55M08 55M09 55M10 55M11 Catalog Number for the entire log set: 55M02 3 4 6 5 Align The Hole On The Log (5) Over The Locating Pin And Postition The Notch Over The Grate As Shown 1 4 Locating Pins 2 Align Groove At The Bottom Of Log (1) Over The Grate And Push It Towards The Rear.
EDV4035 & EDV4540 Log Placement Log Number 1 2 3 4 5 6 Description Part Number Log, Rear Log, Diagonal/Left Log, Diagonal/Right Log, Front/Left Log, Top/Right Log, Front/Center 55M12 55M13 55M14 55M15 55M16 55M17 1 2 Catalog Number for the entire log set: 55M03 3 4 6 5 1 Align The Hole On The Log (5) Over The Locating Pin And Postition The Notch Over The Grate As Shown 4 Locating Pins 5 Align Groove At The Bottom Of Log (1) Over The Grate And Push It Towards The Rear.
Burner Adjustments (QUALIFIED TECHNICIANS ONLY) Flame Appearance and Sooting Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in the body of the flame. When the appliance is first lit, the entire flame may be blue and will gradually turn yellowishorange during the first 15 minutes of operation. If the flame remains blue, or if the flame is orange with evidence of sooting (black tip), the air shutter opening may need to be adjusted.
Burner FLAME Adjustments WARNINGS • Air shutter adjustment should only be performed by a qualified professional service technician. • Ensure front glass panel are in place and sealed during adjustment. 1. Refer to Figures 9, 10 and 11 for proper flame appearance. To adjust the flame, rotate the adjustment rod toward the back or toward the front of the fireplace (rod located in the lower control area). Position the air shutter to the factory setting as shown in the table in Figure 12. 2.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous appliance operation. Electronic Wiring Diagram (Honeywell) Showing the Blower Wiring for the Optional FBK-100 and FBK-200 Kits Electronic Wiring Diagram (Honeywell) Showing the Blower Wiring for the Optional FBK-250 Kits 1. If any of the original wire as supplied must be replaced, 1. it must be replaced with Type AWM 105°C – 18 GA. wire. 2. 120V, 60Hz – Less than 3 amps. 1.
ACCESSORY COMPONENTS Product Reference Information Cat. No. Model Ship. Weight Ship. Volumn H2000 EDV3530NM 78 lb. 9.09 cu. ft. H2001 EDV3530PM 78 lb. 9.09 cu. ft. H2006 EDV3530NE 78 lb. 9.09 cu. ft. H2002 EDV4035NM 86 lb. 10.61 cu. ft. H2003 EDV4035PM 86 lb. 10.61 cu. ft. H2007 EDV4035NE 86 lb. 10.61 cu. ft. H2004 EDV4540NM 108 lb. 14.01 cu. ft. H2005 EDV4540PM 108 lb. 14.01 cu. ft. H2008 EDV4540NE 108 lb. 14.01 cu. ft.
Accessory Components Continued (FBK-200 Models Only) Hood Kits Forced Air Blower Kits -Single Speed 80L84 FBK-100 -Variable Speed with wall-mountable switch 80L85 FBK-200 -Variable Speed with unit-mountable switch 80L86 FBK-250 Forced Air Kit Model No. Clean Face Panel Kits Model No. The FBK-100 blower provides constant velocity forced air circulation. The FBK-200 assembly with variable speed, wall-mountable switch provides variable speed forced air circulation.
Accessory Components Continued ON/OFF Wall Switch Kit 85L87 FWSK ON/OFF Wall Switch Kit 2-Piece Louver Kits Model No. EDV3530 EDV4035 EDV4540 Catalog No. Model No. Polished Brushed Brass Stainless 96L05 96L09 2LVR35PB 2LVR35BS 96L06 96L10 2LVR40PB 2LVR40BS 96L07 96L11 2LVR45PB 2LVR45BS The 2-piece polished brass or brushed stainless louver kits may be used to replace either the middle charcoal louver of each louver set, or the charcoal louver in each louver set closest to the glass door.
Accessory Components Continued Style View Doors Style View Doors come in 4 beautiful styles. They are easy to install and will not require hardware to attach them to the standard glass door frame. The door includes heavy duty magnet door latches and functional twin-pane doors. Arch Design Square Design Square Pane Design Arch Pane Design ARCH DESIGN KITS Cat. No.
Accessory Components Continued Style View Doors Continued Style View Doors also come in a Tall Arch Pane Design. Two distinctive grille kits, the “Crescents” and “Sunrise” design, are also offered seperately. They are easy to install and will not require hardware to attach them to the standard glass door frame. The door includes heavy duty magnet door latches and functional twin-pane doors. TALL ARCH PANE DOORS Cat. No.
Maintenance Schedule Annually (Before the onset of the Burning Season) Maintenance Task Accomplishing Person Procedure Inspecting/Cleaning Burner, Logs and Controls Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping for leaks. Vacuum the control compartment, fireplace logs and burner area.
Lighting Instructions – Millivolt GAS VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted with a piezo ignitor. When lighting the pilot, follow these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas.
INSTRUCTIONS D’ALLUMAGE – VANNE GAZ Millivolt POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. A. Cet appareil est muni d’une veilleuse qui doit être allumée avec un allumeur piézo-électrique. Lorsque vous allumez la veilleuse, suivre exactement ces instructions. B.
Lighting Instructions — Electronic FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
INSTRUCTIONS D’ALLUMAGE — Electronic POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. A. Lorsque vous allumez l’appareil, suivez exactement ces instructions. B.
TROUBLESHOOTING THE Millivolt GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. SYMPTOM 1. Spark ignitor will not light pilot after repeated triggering of ignitor button. CORRECTIVE ACTION A. Defective ignitor (no spark at electrode).
Troubleshooting the Electronic Ignition System Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. Symptom Possible causes 1. Burner will not light. Corrective action A. Faulty Valve System. See Below. B. “OFF/ON” or wall switch defective. Disconnect the two black wires from the wire nuts.
Replacement Parts List Item No. Description EDV3530 EDV4035 Part No. Qty. Part No. EDV4540 Qty. Part No. Qty.
Replacement Parts 10 1 17 31 2 5 15 EDV3530 16 12 11 EDV4035 & EDV4540 21 30 19 8 18 13 14 9 20 36 6 33 2 34 32 7 3 40 35 41 4 42 43 31 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2003 Lennox Hearth Products P/N 875021M REV.