User Guide

20-to 30-Ton Packaged Rooftop Units
QUICK REFERENCE GUIDE
Unit MCA & MOCP Electrical Data (Standard Indoor Fan Motor)
LGH/LCH
Voltage HP MCA MOCP
242H
208-230/3 7.5 99 110
460/3 7.5 54 60
575/3 7.5 38 45
300H
208-230/3 7.5 135 150
460/3 7.5 64 70
575/3 7.5 49 50
360H
208-230/3 7.5 145 150
460/3 7.5 71 80
575/3 7.5 54 60
20- to 30-Ton Packaged Rooftop Performance Data (Gas or Electric Heat)
Size(Tons)
20 Ton 25 Ton 25 Ton 30 Ton 30 Ton
Effi ciency
High High High High High
Model Number
LCH / LGH
242H4V
LCH / LGH
300H4V
LCH / LGH
300H4M
LCH / LGH
360H4V
LCH / LGH
360H4M
Blower Type
VAV VAV MSAV VAV MSAV
Net Cooling Capacity (Btuh)
238,000 300,000 300,000 350,000 350,000
Cooling Stages
4 4 4 4 4
Nominal Supply Air (cfm)
6800 8100 8100 8600 8600
IEER
15.5 14.3 14.4 13.5 14.0
EER
12.3 (LGH)
12.5 (LCH)
11.6 11.6
10.6 (LGH)
10.8 (LCH)
10.6 (LGH)
10.8 (LCH)
Gas Heat Size,
(kBtuh)( stages)
260 (4)
360 (4)
480 (4)
260 (4)
360 (4)
480 (4)
260 (4)
360 (4)
480 (4)
260 (4)
360 (4)
480 (4)
260 (4)
360 (4)
480 (4)
Electric Heat Size (kW) 30, 45, 60, 90, 120
Blower Motor Size (HP) 5, 7.5, 10 5, 7.5, 10 5, 7.5, 10 5, 7.5, 10 5, 7.5, 10
Net. Weight (lbs.) G/E 3,107 3,107 3,107 3,107 3,107
Net. Weight (lbs.) E/E 2,997 2,997 2,997 2,997 2,997
Weight—Shipping (lbs.) G/E 3,317 3,317 3,317 3,317 3,317
Weight—Shipping (lbs.) E/E 3,207 3,207 3,207 3,207 3,207
Cabinet Size—H x W x L (in.) 65 x 91 x 145
Filter (Quantity/Size ) (12) 20 x 20 x 2
Sound (dBA) 95 95 95 95 95
Option Factory Field
Indoor air quality
MERV 8 Filters
MERV 13 Filters
MERV 16 Filters
Replacement Media Filter with Metal Mesh
IAQ (CO
2
) Sensors
Electrical
Electrical Voltage
Disconnect Switch
GFI Service Outlets
Weatherproof Cover for GFI
Phase Monitor
Electric Heat
SCR (Silicon Controlled Rectifi er)
Electric Heat Control
4
Economizer
Economizer – Downfl ow or Horizontal
with Barometric Relief
Economizer Controls – Sensible
Economizer Controls – Single Enthalpy
Economizer Controls – Differential Enthalpy
Economizer Controls – Global Control
Downfl ow or Horizontal Barometric Relief
Dampers- Hood Furnished
Outdoor air
Manual Outdoor Air Dampers
Motorized Outdoor Air Dampers
Power exhaust
High Static with VFD
High Static with VFD and Bypass
Standard Static
Humiditrol condenser reheat
Humiditrol
®
Dehumidifi cation System
Humiditrol Sensor Kit, Remote mounted
Roof curbs/ceiling diffusers
Roof Curbs
Ceiling Diffusers
Factory- and Field-Installed Options
Option Factory Field
Cooling
Drain Pan Overfl ow Switch
PVC or Copper Condensate Drain Trap
Stainless Steel Condensate Drain Pan
Blower
Blower – Supply Air Motors
Blower – Supply Air Drive Kits
Heating
Combustion Air Intake Extensions
Gas Heat Input
Low Temperature Vestibule Heater
LPG/Propane Conversion Kits
Stainless Steel Heat Exchanger
Vertical Vent Extension
Cabinet
Combination Coil/Hail Guards
Corrosion Protection (indoor coil/outdoor coil)
Controls
CS3000, CS7500, and CS8500
Commercial Thermostats
Blower Proving Switch
BACnet
®
Module
LonTalk
®
Module
Novar
®
LSE
L Connection
®
Building Automation System
Dirty Filter Switch
Fresh Air Tempering
Smoke Detector Supply and/or Return
Supply Static Limit Switch
Discharge Air Temperature Sensor
Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at 1-800-4-LENNOX
©2023 Lennox Industries, Inc. (14G47) 3/23 PC92164
RETURN
OPENING
SUPPLY
OPENING
61-1/2”
86-1/8”
21”
16”
RL
L
Model No.
Length Return Air
L RL
242 to 360 115-1/8 79-1/2
For 242-360 Models

Summary of content (1 pages)