Product Overview

iComfort
®
S30 Ultra Smart Thermostat / Page 6
SYSTEM COMPONENT TYPES
System Type iComfort
®
Thermostat
Outdoor Unit Type
(iComfort
®
Communicating or
Non-Communicating)
1
Indoor Unit Type
(iComfort
®
Communicating)
1
Indoor Unit Type
(Non-Communicating)
2
Equipment Interface
Module (EIM) Required
Air Conditioner Required Either type may be used EL296V, SL280V, SL280NV,
SL297NV or SLP99V Furnace
Most Furnaces
Required Either type may be used CBA38MV
Air Handler
Most Air Handlers
Heat Pump Required Either type may be used EL296V, SL280V, SL280NV,
SL297NV or SLP99V Furnace
Most Furnaces
Required Either type may be used CBA38MV
Air Handler
Most Air Handlers
1
Indoor unit must contain the iComfort
®
Communicating Control or optional Equipment Interface Module (EIM). A non-communicating outdoor unit may be used (but some
system features will be reduced).
2
Not for use with XC20/XP20 or SL28XCV/SL25XPV outdoor units. Indoor unit must be factory iComfort
®
Communicating when iComfort
®
S30 thermostat is used with XC20/
XP20 or SL28XCV/SL25XPV outdoor units.
CONTROL ORDERING INFORMATION
iComfort S30 Ultra-Smart Thermostat Components
Equipment Interface Module (EIM)
Description Catalog No.
iComfort S30 Ultra-Smart Thermostat (includes high denition display with Subbase and Smart Hub Controller)
Dimensions:
High Denition Display with Subbase (H x W x D) - 5 x 7-1/4 x 1 in.
Smart Hub Controller Case (H x W x D) - 4-1/2 x 4-1/2 x 1-1/2 in.
Antenna length - 7-1/4 in.
19V30
Equipment Interface Module (EIM) - For most non-communicating HVAC systems including dual-fuel capable non-
communicating heat pumps
Dimensions: (H x W x D): 6-1/8 x 7-1/2 x 1-3/8 in. (156 x 191 x 35 mm)
10T50
1
Optional Outdoor Air Temperature Sensor X2658
2
Discharge Air Temperature Sensor 88K38
1
The Optional Outdoor Air Temperature Sensor may be used with an iComfort
®
equipped outdoor unit for a secondary (alternate) sensor reading.
The Optional Outdoor Air Temperature Sensor may be ordered for use with a conventional outdoor unit.
NOTE - The Optional Outdoor Air Temperature Sensor is REQUIRED for dual-fuel applications with a non-communicating heat pump outdoor unit.
2
Required with Air Handler applications when using EVENHEATER
®
option. Optional on all other applications for service diagnostics.