Product Overview

iComfort
®
S30 Ultra Smart Thermostat / Page 33
INSTALLER SETTINGS
EQUIPMENT (continued)
Thermostat
(About)
Model Number
Serial Number
Software Revision
Hardware Revision
Language Support
Equipment Type name
(Adjust Settings)
Screen Locked (Prevents tampering with thermostat
settings)
Unlocked (no security)
Partially Locked (prevents tampering with the menu
settings, setpoints can be adjusted)
Locked (prevents tampering with the thermostat)
Display Outdoor Weather (on/off)
Display Air Quality (on/off)
Outdoor Temperature Source
Off
Internet
Sensor
Display Indoor Humidity (on/off)
Screen Saver (on/off)
Off
Weather
Power Save
Weather displays the current weather conditions screen.
Power Save displays a blank screen until the screen is
touched or the proximity sensor is activated.
Auto Brightness (on/off)
If Auto Brightness is turned off a slider appears to
manually adjust the brightness of the display.
Brightness Value (0 to 100%, default is 80%)
Proximity Control (on/off)
Proximity sensor turns on the display backlight at a
specic distance.
Wide Setpoint (on/off)
Reset Thermostat (factory default settings)
Reset Options
Restart Smart Hub
Re-Congure System
Reset HVAC Equipment (resets all HVAC equipment)
Factory Reset Thermostat
Factory Reset Smart Hub (resets Smart Hub to factory
state)
NOTIFICATIONS SCREEN
Provides information for active and previous notications.
When selecting either a cleared or active notication a
brief description and alert code will be displayed.
Notications are categorized by Smart Hub, Air Handler or
Furnace, Air Conditioner or Heat Pump, Zoning Control (if
installed) and the iComfort
®
S30 Thermostat.
To expand a notication for more details of the alert code,
touch the down arrow to expand the description.
Touch the clear button to move the notication to the
cleared area.
TESTS SCREEN
A variety of system tests can be performed by the
installer.
Various tests are available depending on equipment in the
system. By default all items to be tested are enabled.
Verify Airow Per Zone
Blower Circulation Airow
Heating Circulation Airow
Cooling Circulation Airow
Touch the down arrow next to each airow type to adjust
the individual airow. Use the plus and minus buttons to
adjust airow in 5 cfm increments. Press and hold arrow
for rapid adjustment.
If no zoning is installed, zone airow settings will be
for zone 1 only. If zoning equipment is detected by the
system, zones 1 through 4 will be listed.
Select Tests to Run
Selecting a specic test will uncheck the item. When a
specic set of tests are completed the results will be
displayed on the screen next to the tested item. Touch and
scroll to see all tested items. Touch Continue to advance
to the next test.
FEATURES