INSTALLER SETTINGS
EQUIPMENT (continued)
Air Handler
(About)
Unit Code
Language Support
Equipment Type name
Unit Model Number
Unit Serial Number
Unit Nominal Capacity
Number of Heating Stages
Heating Capacity by Stage
Indoor Blower CFM Range
Control Software Revision
Control Model Number
Control Serial Number
Control Hardware Revision
Discharge Air Temp Sensor
Outdoor Air Temp Sensor
Protocol Revision Number
Device Product Level
Factory Installed Transformer
24VAC Average Power Consumption
24VAC Peak Power Consumption
Line Voltage Average Power Consumption
Line Voltage Peak Power Consumption
Compatible Devices List
Application Code Memory Size
Microcontroller Part Number
(Adjust Settings)
Equipment Name (Keyboard tool)
Electric Heating Airow
Low Cooling Airow (XC21, XP21)
High Cooling Airow
Airow Prole - Cooling (default is 1)
No Delays
On (No delays); Off (45 sec. delay)
On (82% for 7.5 min.); Off (No delays)
On (50% for 30 sec., 82% for 7.5 min.); Off (50% for 30
sec.)
XC21, XP21
Low HP Airow (XP21)
High HP Airow
Continuous Indoor Blower Airow (450 to 2150 cfm,
default is 800 cfm)
Humidication Airow (Humidier)
All airow parameters are determined by settings in
communicating equipment and are dependent on the
capacity of the unit.
Dehumidication Airow (Dehumidier)
(60 to 80%, default is 70%)
Dehumidication Airow is 60 to 80% reduction of the
High Cooling Airow parameter.
(Adjust Settings)
Delay Settings
Heating Indoor Blower OFF
(0 to 10 sec., default is 10 sec.)
Heating Indoor Blower ON
(0 to 5 sec., default is 0 sec.)
Cooling Indoor Blower OFF
(0 to 30 sec., default is 0 sec.)
Cooling Indoor Blower ON
(0 to 10 sec., default is 2 sec.)
HP Indoor Blower OFF
(0 to 60 sec., default is 45 sec.)
HP Indoor Blower ON
(0 to 30 sec., default is 0 sec.)
Reset Air Handler (factory default settings)
Zoning Control
(About)
Unit Code
Language Support
Equipment Type name
Control Software Revision
Control Model Number
Control Serial Number
Control Hardware Revision
Protocol Revision Number
Device Product Level
24VAC Average Power Consumption
24VAC Peak Power Consumption
Compatible Devices List
Application Code Memory Size
Microcontroller Part Number
Maximum Number of Zones
Supported Damper Types
(Adjust Settings)
Equipment Name (Keyboard tool)
Zone 1 Temperature Reading Calibration (–5 to 5°F,
default is 0°F)
Zone 2 Temperature Reading Calibration (–5 to 5°F,
default is 0°F)
Zone 3 Temperature Reading Calibration (–5 to 5°F,
default is 0°F)
Zone 3 Temperature Reading Calibration (–5 to 5°F,
default is 0°F)
Reset Zoning Control (factory default settings)
FEATURES