Product Overview
Table Of Contents
- ICOMFORT® S30 THERMOSTAT
- BASIC INFOMATION
- INSTALLER SETTINGS
- USER SETTINGS
- ACCOUNT SCREEN
- ADVANCED SETTINGS (INSTALLER SETTINGS)
- AWAY SCREEN
- AWAY SETTINGS SCREEN
- COOL MENU SCREEN
- DISPLAY SCREEN
- EDIT SCHEDULES SCREEN
- FAN SCREEN
- FEELS LIKE SCREEN
- GENERAL SCREEN
- HEAT/COOL SCREEN
- HEAT MENU SCREEN
- HOME INFO SCREEN
- HOME SCREEN (Thermostat ON)
- HUMIDITY SCREEN (Humidity Control)
- IHARMONY ZONING SCREEN (if equipped)
- MENU SCREEN
- MODES/SCHEDULES SCREEN
- NAME SCREEN
- NOTIFICATIONS (REMINDERS) SCREEN
- PUREAIR™ S PERFORMANCE SCREEN
- SCHEDULE HOLD SCREEN
- SCHEDULES SCREEN
- SETTINGS SCREEN
- VENTILATION SCREEN (Fresh Air Damper/HRV/ERV)
- WEATHER FORECAST SCREEN
- WI-FI SCREEN
- ZONING SCREEN
- REVISIONS
iComfort
®
S30 Ultra Smart Thermostat / Page 30
EQUIPMENT (continued)
Air Conditioner or Heat Pump
(About)
• Language Support
• Equipment Type Name
• Unit Model Number
• Unit Serial Number
• Unit Nominal Capacity
• Number of Heating Stages (Heat Pump)
• Number of Cooling Stages
• Heating Capacity by Stage (Heat Pump)
• Cooling Capacity by Stage
• Control Software Revision
• Control Model Number
• Control Serial Number
• Control Hardware Revision
• Outdoor Air Temp Sensor
• Operating Temperature Limits
• Protocol Revision Number
• Device Product Level
• 24VAC Average Power Consumption
• 24VAC Peak Power Consumption
• Line Voltage Average Power Consumption
• Line Voltage Peak Power Consumption
• Outdoor Fan RPM Prole (single stage)
• OD Inverter Model Number (modulating)
• OD Inverter FW Revision (modulating)
• Unit Code
• Compatible Devices List
• Application Code Memory Size
• Microcontroller Part Number
(Adjust Settings)
• Equipment Name (Keyboard tool)
• Compressor Short Cycle Delay (60 to 300 sec., default is
300 sec.)
• Defrost Termination Temp (Heat Pump only) (50 to
100°F, default is 50°F)
• Automatic Max Defrost (Heat Pump only) (On/Off,
default is Off)
• Max Defrost by Weather (Heat Pump only) (On/Off,
default is Off)
Max Defrost by Weather uses the default Internet weather
source to determine when a defrost cycle is required..
• Compressor Shift Delay (Heat Pump only) (On/Off,
default is On)
• High Normal Cooling Airow (450 to 2000 cfm., default
is 1800 cfm)
• Low Normal Cooling Airow (450 to 2000 cfm., default
is 900 cfm)
• High Normal HP Heating Airow (450 to 2000 cfm.,
default is 1806 cfm)
• Low Normal HP Heating Airow (450 to 2000 cfm.,
default is 1150 cfm)
• Dehum Airow Adjustment Adder (0 to 30°F, default is
0°F)
SL28XCV, SL25XPV, XC20, XP20
• Fan Cycling (On/Off, default is Off)
EL18XP1, XP21
• Reset Air Conditioner / Heat Pump (factory default
settings)
INSTALLER SETTINGS
FEATURES