Product Overview

iComfort
®
S30 Ultra Smart Thermostat / Page 30
EQUIPMENT (continued)
Air Conditioner or Heat Pump
(About)
Language Support
Equipment Type Name
Unit Model Number
Unit Serial Number
Unit Nominal Capacity
Number of Heating Stages (Heat Pump)
Number of Cooling Stages
Heating Capacity by Stage (Heat Pump)
Cooling Capacity by Stage
Control Software Revision
Control Model Number
Control Serial Number
Control Hardware Revision
Outdoor Air Temp Sensor
Operating Temperature Limits
Protocol Revision Number
Device Product Level
24VAC Average Power Consumption
24VAC Peak Power Consumption
Line Voltage Average Power Consumption
Line Voltage Peak Power Consumption
Outdoor Fan RPM Prole (single stage)
OD Inverter Model Number (modulating)
OD Inverter FW Revision (modulating)
Unit Code
Compatible Devices List
Application Code Memory Size
Microcontroller Part Number
(Adjust Settings)
Equipment Name (Keyboard tool)
Compressor Short Cycle Delay (60 to 300 sec., default is
300 sec.)
Defrost Termination Temp (Heat Pump only) (50 to
100°F, default is 50°F)
Automatic Max Defrost (Heat Pump only) (On/Off,
default is Off)
Max Defrost by Weather (Heat Pump only) (On/Off,
default is Off)
Max Defrost by Weather uses the default Internet weather
source to determine when a defrost cycle is required..
Compressor Shift Delay (Heat Pump only) (On/Off,
default is On)
High Normal Cooling Airow (450 to 2000 cfm., default
is 1800 cfm)
Low Normal Cooling Airow (450 to 2000 cfm., default
is 900 cfm)
High Normal HP Heating Airow (450 to 2000 cfm.,
default is 1806 cfm)
Low Normal HP Heating Airow (450 to 2000 cfm.,
default is 1150 cfm)
Dehum Airow Adjustment Adder (0 to 30°F, default is
0°F)
SL28XCV, SL25XPV, XC20, XP20
Fan Cycling (On/Off, default is Off)
EL18XP1, XP21
Reset Air Conditioner / Heat Pump (factory default
settings)
INSTALLER SETTINGS
FEATURES