Product Overview
Table Of Contents
- ICOMFORT® S30 THERMOSTAT
- BASIC INFOMATION
- INSTALLER SETTINGS
- USER SETTINGS
- ACCOUNT SCREEN
- ADVANCED SETTINGS (INSTALLER SETTINGS)
- AWAY SCREEN
- AWAY SETTINGS SCREEN
- COOL MENU SCREEN
- DISPLAY SCREEN
- EDIT SCHEDULES SCREEN
- FAN SCREEN
- FEELS LIKE SCREEN
- GENERAL SCREEN
- HEAT/COOL SCREEN
- HEAT MENU SCREEN
- HOME INFO SCREEN
- HOME SCREEN (Thermostat ON)
- HUMIDITY SCREEN (Humidity Control)
- IHARMONY ZONING SCREEN (if equipped)
- MENU SCREEN
- MODES/SCHEDULES SCREEN
- NAME SCREEN
- NOTIFICATIONS (REMINDERS) SCREEN
- PUREAIR™ S PERFORMANCE SCREEN
- SCHEDULE HOLD SCREEN
- SCHEDULES SCREEN
- SETTINGS SCREEN
- VENTILATION SCREEN (Fresh Air Damper/HRV/ERV)
- WEATHER FORECAST SCREEN
- WI-FI SCREEN
- ZONING SCREEN
- REVISIONS
iComfort
®
S30 Ultra Smart Thermostat / Page 27
INSTALLER SETTINGS
• Electric Heat Control Mode (Air Handler) (Standard/
Evenheat)
• EvenHeat Discharge Temperature (85 to 130°F,
default is 85°F)
EL18XC1, XC/XP21
• Gas Heat Control Mode (Staged, Variable Capacity or
Load Tracking Variable Capacity)
SLP99
• Number of Gas Heating Stages (1, 2, 3, or 4, default is
4)
Staged
• Modulating Gas Heating Steady State PI Gain (Less
Aggressive, More Aggressive or Standard)
• Modulating Gas Heating Step Change PI Gain (Less
Aggressive, More Aggressive or Standard)
• Modulating Gas Heating Cycles Per Hour (4.0 to 10.0,
default is 6.0)
Load Trk. Var. Cap.
• Gas Heating Activation Temp Difference (5 to 10°F,
default is 1.5°F)
D. Fuel
• Cooling Mode (two-stage cooling systems only)
(Normal, Comfort)
Normal - 2nd stage is locked in until the demand is
satised.
Comfort - 2nd stage is energized or de-energized based on
demand to maintain comfort.
EL18XC/P1, XC/XP21
• Modulating Cooling Steady State PI Gain (Less
Aggressive, More Aggressive or Standard)
• Modulating Cooling Step Change PI Gain (Less
Aggressive, More Aggressive or Standard)
• Modulating Cooling Cycles Per Hour (3.0 to 6.0, default
is 4.0)
SL28XCV, XP20
• Modulating HP Heating Steady State PI Gain (Less
Aggressive, More Aggressive or Standard)
• Modulating HP Heating Step Change PI Gain (Less
Aggressive, More Aggressive or Standard)
• Modulating HP Heating Cycles Per Hour (3.0 to 6.0,
default is 4.0)
• Modulating HP Electric Heating Switching Point (0.0 to
2.0, default is 1.0)
SL25XPV, XP20
• Aux Heating Activation Threshold (0 to 10°F, default is
2.5°F)
Air Handler
CONTROL CENTER SCREEN
Provides access to the dealer for performing various
functions.
• Equipment Settings
• Notications
• Tests
• Diagnostics
• Installation Report
• Information
• Exit Button (returns to Home Screen)
The Control Center can also be accessed from the Home
Screen under the Menu Button > Advanced Settings.
EQUIPMENT
Smart Hub
(About)
• Language Support
• Equipment Type name
• Control Software Revision
• Control Model Number
• Control Serial Number
• Control Hardware Revision
• Protocol Revision Number
• Device Product Level
• 24VAC Average Power Consumption
• 24VAC Peak Power Consumption
• Compatible Device List
• Application Code Memory Size
• Microcontroller Part Number
(Adjust Settings)
• Equipment Name (Keyboard tool)
• Temp Reading Calibration (–5 to 5°F, default is 0°F)
• Humidity Reading Calibration (–10 to 10% RH, default is
0%)
• Smooth Setback Recovery (Enabled/Disabled)
FEATURES