INSTALLER SETTINGS
Electric Heat Control Mode (Air Handler) (Standard/
Evenheat)
EvenHeat Discharge Temperature (85 to 130°F,
default is 85°F)
EL18XC1, XC/XP21
Gas Heat Control Mode (Staged, Variable Capacity or
Load Tracking Variable Capacity)
SLP99
Number of Gas Heating Stages (1, 2, 3, or 4, default is
4)
Staged
Modulating Gas Heating Steady State PI Gain (Less
Aggressive, More Aggressive or Standard)
Modulating Gas Heating Step Change PI Gain (Less
Aggressive, More Aggressive or Standard)
Modulating Gas Heating Cycles Per Hour (4.0 to 10.0,
default is 6.0)
Load Trk. Var. Cap.
Gas Heating Activation Temp Difference (5 to 10°F,
default is 1.5°F)
D. Fuel
Cooling Mode (two-stage cooling systems only)
(Normal, Comfort)
Normal - 2nd stage is locked in until the demand is
satised.
Comfort - 2nd stage is energized or de-energized based on
demand to maintain comfort.
EL18XC/P1, XC/XP21
Modulating Cooling Steady State PI Gain (Less
Aggressive, More Aggressive or Standard)
Modulating Cooling Step Change PI Gain (Less
Aggressive, More Aggressive or Standard)
Modulating Cooling Cycles Per Hour (3.0 to 6.0, default
is 4.0)
SL28XCV, XP20
Modulating HP Heating Steady State PI Gain (Less
Aggressive, More Aggressive or Standard)
Modulating HP Heating Step Change PI Gain (Less
Aggressive, More Aggressive or Standard)
Modulating HP Heating Cycles Per Hour (3.0 to 6.0,
default is 4.0)
Modulating HP Electric Heating Switching Point (0.0 to
2.0, default is 1.0)
SL25XPV, XP20
Aux Heating Activation Threshold (0 to 10°F, default is
2.5°F)
Air Handler
CONTROL CENTER SCREEN
Provides access to the dealer for performing various
functions.
Equipment Settings
Notications
Tests
Diagnostics
Installation Report
Information
Exit Button (returns to Home Screen)
The Control Center can also be accessed from the Home
Screen under the Menu Button > Advanced Settings.
EQUIPMENT
Smart Hub
(About)
Language Support
Equipment Type name
Control Software Revision
Control Model Number
Control Serial Number
Control Hardware Revision
Protocol Revision Number
Device Product Level
24VAC Average Power Consumption
24VAC Peak Power Consumption
Compatible Device List
Application Code Memory Size
Microcontroller Part Number
(Adjust Settings)
Equipment Name (Keyboard tool)
Temp Reading Calibration (–5 to 5°F, default is 0°F)
Humidity Reading Calibration (–10 to 10% RH, default is
0%)
Smooth Setback Recovery (Enabled/Disabled)
FEATURES