Product Overview
Table Of Contents
- ICOMFORT® S30 THERMOSTAT
- BASIC INFOMATION
- INSTALLER SETTINGS
- USER SETTINGS
- ACCOUNT SCREEN
- ADVANCED SETTINGS (INSTALLER SETTINGS)
- AWAY SCREEN
- AWAY SETTINGS SCREEN
- COOL MENU SCREEN
- DISPLAY SCREEN
- EDIT SCHEDULES SCREEN
- FAN SCREEN
- FEELS LIKE SCREEN
- GENERAL SCREEN
- HEAT/COOL SCREEN
- HEAT MENU SCREEN
- HOME INFO SCREEN
- HOME SCREEN (Thermostat ON)
- HUMIDITY SCREEN (Humidity Control)
- IHARMONY ZONING SCREEN (if equipped)
- MENU SCREEN
- MODES/SCHEDULES SCREEN
- NAME SCREEN
- NOTIFICATIONS (REMINDERS) SCREEN
- PUREAIR™ S PERFORMANCE SCREEN
- SCHEDULE HOLD SCREEN
- SCHEDULES SCREEN
- SETTINGS SCREEN
- VENTILATION SCREEN (Fresh Air Damper/HRV/ERV)
- WEATHER FORECAST SCREEN
- WI-FI SCREEN
- ZONING SCREEN
- REVISIONS
iComfort
®
S30 Ultra Smart Thermostat / Page 25
3 - HOME ADDRESS SCREEN
Enter the information for the home that this thermostat is
installed in.
• Address 1
• Address 2
• State
• City
• Zip/Postal Code
Use the keyboard tool to manually input this information.
4 - EQUIPMENT FOUND SCREEN
equipment found
welcome to iComfort
previous continue
iHarmony
(3)
iComfort S30
Smart Hub
system
f
t
S
30
0
m
(
3
)
SLO185V
iCo
m
f
fo
r
t
S
30
0
air handler
previou
dehumidifier
humiditrol
1st stage
a/c unit
continu
e
filter
PureAir
Smart
Hub
filter
humidifier
hcwp18
+/-
equipment
non-communicating
A visual representation of the iComfort
®
Communicating
equipment discovered during the set-up.
If an iComfort
®
Equipment Interface Module (EIM) is part
of the system and congured as either a furnace or air
handler, the indoor unit will appear as EIM-Furnace or
EIM-Air Handler. When using an EIM the outdoor unit may
be either a Lennox communicating or any standard non-
communicating outdoor unit.
Touch the +/- icon at the upper-right of the screen to add
non-communicating equipment.
After non-communicating equipment has been added it
will also appear on the Equipment Found Screen.
ADD / REMOVE EQUIPMENT SCREEN
Add non-communicating equipment to the system to be
controlled by the thermostat.
• Outdoor Unit Type
(Not Installed, 1 Stage AC Unit, 2 Stage AC Unit, 1 Stage
HP Unit, 2 Stage HP Unit)
Outdoor Unit Type selection only appears if a
communicating outdoor unit is not detected during setup.
• Outdoor Unit Capacity
(18 to 60 kBtuh, default is 36 kBtuh)
• Outdoor Unit 1st Stage Capacity
(30 to 100 kBtuh (default is 70 kBtuh)
NOTE - If Outdoor Unit is non-communicating type, screen
will display the above parameters to set.
• Ventilator Type
(None, Fresh Air Damper, 1 Stage HRV, 2 Stage HRV, 1
Stage ERV, 2 Stage ERV)
• Humidier
(Not Installed, Power (120VAC) Humidier, Bypass
(24VAC) Humidier, Bypass and Power Humidier)
NOTE - If Air Handler is used, Bypass is the only Humidier
option.
• Dehumidier
(Not Installed, Humiditrol, Auxiliary Dehumidier)
INSTALLER SETTINGS
FEATURES