Product Overview
Table Of Contents
- ICOMFORT® S30 THERMOSTAT
- BASIC INFOMATION
- INSTALLER SETTINGS
- USER SETTINGS
- ACCOUNT SCREEN
- ADVANCED SETTINGS (INSTALLER SETTINGS)
- AWAY SCREEN
- AWAY SETTINGS SCREEN
- COOL MENU SCREEN
- DISPLAY SCREEN
- EDIT SCHEDULES SCREEN
- FAN SCREEN
- FEELS LIKE SCREEN
- GENERAL SCREEN
- HEAT/COOL SCREEN
- HEAT MENU SCREEN
- HOME INFO SCREEN
- HOME SCREEN (Thermostat ON)
- HUMIDITY SCREEN (Humidity Control)
- IHARMONY ZONING SCREEN (if equipped)
- MENU SCREEN
- MODES/SCHEDULES SCREEN
- NAME SCREEN
- NOTIFICATIONS (REMINDERS) SCREEN
- PUREAIR™ S PERFORMANCE SCREEN
- SCHEDULE HOLD SCREEN
- SCHEDULES SCREEN
- SETTINGS SCREEN
- VENTILATION SCREEN (Fresh Air Damper/HRV/ERV)
- WEATHER FORECAST SCREEN
- WI-FI SCREEN
- ZONING SCREEN
- REVISIONS
iComfort
®
S30 Ultra Smart Thermostat / Page 19
HUMIDITY SCREEN (Humidity Control)
• Off (default)
• Humidify
• Normal, Max, Dewpoint
• Dehumidify
• Normal, Max, Climate IQ
®
(Auto)
• Dewpoint (on/off)
• Humidify + Dehumidify
Dewpoint setting is only available with remote Outdoor
Temperature Sensor. Sensor is furnished as standard
with iComfort
®
Communicating outdoor units, optional for
conventional units (-15 to 15%, adjustable, default is 0%).
Humidication Control Center
normal setting is recommended for moderate climates.
Operates the humidier when there is a call for heating
and humidication.
max setting is recommended for drier climates. Operates
the humidier when there is a call for humidication only.
Dehumidication Control Center
normal setting is recommended for moderate climates.
Operates the dehumidier when there is a call for cooling
and dehumidication.
max setting is recommended for humid climates.
Operates the dehumidier when there is a call for
dehumidication only. May cool beyond desired setpoint
by 2 degrees.
Climate IQ
®
setting monitors regional weather conditions and
automatically removes excess humidity when necessary.
NOTE - Climate IQ
®
settings are only available for
iComfort
®
Communicating outdoor units (SL28XCV/
SL25XPV, XC21/XC21, XC20/XP20) without any optional
humidication/dehumidication equipment installed.
• Humidication Setpoint
(15 to 45% relative humidity, adjustable, default 40%)
• Dehumidication Setpoint
(40 to 60% relative humidity, adjustable, default 50%)
• Overcooling Setpoint (Max or Climate IQ
®
only)
(0 to 4°F, adjustable, default 2°F)
• Humidication (left slider) + Dehumidication (right
slider) Setpoint
(15% to 60%, adjustable, default 15% humidication
and 40% dehumidication)
Adjustable sliders allows Dehumidication/Humidication/
Overcooling Setpoint adjustment.
Depending on humidity/dehumidity mode settings selected
not all settings above may be visible.
USER SETTINGS
IHARMONY ZONING SCREEN (if equipped)
NOTE - Zoning is only available for systems using the
iHarmony
®
Zoning System.
System components include the iComfort
®
S30
thermostat, iHarmony
®
Damper Control Module (DCM),
individual In-Zone Thermostats and Motorized Dampers.
NOTE - Single-stage outdoor units can only be used with
two equal load zones when using the iHarmony
Zoning System.
Variable capacity and two-stage outdoor units can
utilize up to four zones when using the iHarmony
zoning system.
See iHarmony Zoning System Product Specications for
additional information.
• Zoning (on/off)
• Zone 1 (master)
• Zone 2
• Zone 3
• Zone 4
Touch any zone name to edit with the keyboard tool
(maximum 30 characters).
NOTIFICATIONS (REMINDERS) SCREEN
• Replace Filter 1
• Replace Filter 2
• Replace UV Lamp
• Replace Humidier Pad
• Maintenance Reminder and PureAir™ Maintenance
• Disabled (default for all notications)
• 3, 6, 12, 24 Months or Custom date
• Set for Calendar Time or Runtime
• Sensor-Based (PureAir only)
Touch custom to access the Set Date Tool screen to input
custom date settings.
FEATURES