Product Overview

ComfortSense
®
7500 Commercial Touchscreen Thermostat / Page 5
USER SETTINGS (CONTINUED)
USER SETTINGS SCREEN
Fan
On
Auto
Circulate
If set to auto, fan operates only when equipment is
operating and follows a selected schedule.
If set to on, fan runs continuously until it is changed from
the select mode.
If set to circulate, fan follows a selected schedule and also
󰀨
on user setting (1 to 30 minutes). Slide control appears
when circulate is selected.
In auto mode, fan can operate in auto mode, on mode
or circulate mode if it is programmed as such for the
current schedule.
Heat/Cool
Normal
Comfort (2-stage heating or cooling)
Emergency Heat (heat pump systems only)
Bypasses any stages of mechanical heat pump heating
and operates secondary heat source directly for
maximum heating.

Heating Limit, 90°F (default) adjustable (45 to
90°F)
Cooling Limit, 45°F (default) adjustable (45 to
99°F)
Cool Only

Cooling Limit, 45°F (default) adjustable (45 to
99°F)
Humidity
󰀨󰀨
Touch Dehumidify to turn On.
Dehumidify
Dehumidify On
Setpoint - 50% (default) adjustable RH (45 to 60%)
Use the slider to adjust the desired levels.