Indoor Fireplace User Manual
16
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
 WARNINGS
•  Air shutter adjustment should 
only be performed by a quali-
fied professional service tech-
nician.
•  Ensure front glass panel are 
in  place  and  sealed  during 
adjustment.
 CAUTIONS
•  Soot will be produced if the 
air shutter is closed too much.  
Any damage due to sooting, 
resulting  from  improperly 
setting the air shutter, is not 
covered under the warranty.
• The  air  shutter  door  and 
nearby  appliance  surfaces 
are hot.  Exercise caution to 
avoid injury while  adjusting 
flame appearance.
1.  Refer to Figure 13 for proper flame ap-
pearance. To adjust the flame, rotate the 
adjustment rod toward the back or toward 
the front of the fireplace (rod located in 
the lower control area). Position the air 
shutter to the factory setting as shown in 
the table in Figure 14. 
2. Light appliance (follow lighting procedure 
on lighting label in control compartment 
or see the Care and Operation Manual).
3. Allow the burner to operate for at least 15 
minutes while observing the flame con-
tinuously to ensure that the proper flame 
appearance has been achieved.  If the 
following conditions are present, adjust 
accordingly. 
 • Ifameappearsweakorsooty,adjust
the air shutter, incrementally, to a 
more open position until the proper 
flame appearance is achieved.
 • Ifameremainsblue,adjusttheair
shutter, incrementally, to a more 
closed position until the proper flame 
appearance is achieved.
4. Leave the control knob (off/pilot/on) in 
the ON position and the burner OFF/ON 
switch OFF (and remote switches, if ap-
plicable). 
5. When satisfied that the burner flame ap-
pearance is normal, re-install the lower 
control compartment door then proceed 
to finish the installation. 
MILLIVOLT
Thermocouple
Hood Igniter Rod
3/8" Min
(9 mm)
Thermopile
Pilot
Nozzels
Millivolt Appliance Checkout
The  pilot  flame  should  be  steady,  not  lifting 
or floating. Flame should be blue in color with 
traces of orange at the outer edge.
The top  3/8" (10 mm)  at the  pilot  generator 
(thermopile) and the top 1/8" minimum (tip) 
of the quick drop out thermocouple should be 
engulfed in the pilot flame. 
The flame should project 1" (25 mm) beyond the 
hood at all three ports (see Figure 15 ).  Replace 
logs if removed for pilot inspection.
To light the burner; turn “ON” the remote wall 
switch and rotate the gas valve control knob 
counterclockwise to the “ON” position (“ON” 
will be at the top side of the valve).
Electronic Appliance Checkout
To light the burner, turn ‘ON’ the unit mounted 
On/Off switch or the optional remote wall switch.  
Ensure the igniter lights the pilot.   The pilot 
flame should engulf the flame rod as shown 
in Figure 16.
Figure 15
ELECTRONIC
Proper Flame
Adjustment
Pilot
Nozzle
3/8 To 1/2 Inch
(9 mm to 13 mm)
Ground
Electrode
Flame Rod
Hot Surface
Igniter
Figure 16
BURNER FLAME ADJUSTMENTS 
Adjustment Rod Positions 
(when viewed from above)
Figure 14
Main Burner Factory Air Shutter 
Opening Setting - All Models
Model Natural
Gas
Propane
Gas
MPD35ST/PF
1/8”
3.2mm
1/4”
6.4mm
Air Shutter 
Adjusting Rod
Increase Shutter Opening 
In This Direction
Decrease Shutter Opening 
In This Direction
Note - Burners are omitted in this view for clarity.
Orifice
Ref. Air shutter Patent:
U.S. Pat. 5,553,603