Datasheet
4
®
®
www.lemo.com
.. .
● Step 2: Complete the part number
Complete the part numbering by choosing the model depending on your cable and the application.
Verify the fitting to your cable and cable wire
Recommended coaxial cables
250
Part number coding
sheathdielectric
screen
conductor
19 x 0.18
solid
7 x 0.16
7 x 0.16
7 x 0.10
7 x 0.10
7 x 0.10
7 x 0.18
7 x 0.10
7 x 0.10
7 x 0.18
0.90
0.95
0.48
0.48
0.30
0.30
0.30
0.54
0.30
0.30
0.54
PE
PTFE
PE
PE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
2.92
2.95
1.50
1.50
0.87
1.50
1.50
1.50
2.52
0.87
1.50
CuSn
CuAg
CuAg
CuSn
CuSn
CuAg
CuAg
CuAg
CuAg
CuAg
CuAg
CuAg
3.6
1
st
: 3.53
2
nd
: 4.20
2.0
2.0
1.4
2.0
2.0
2.0
3.1
1.37
2.1
PVC
FEP
PVC1
PVC2
FEP
FEP
PFA
PFA
PFA
PFA
FEP
black
black
black
brown
brown
white
white
white
white
brown
Mechanical properties
Type
RG 58 C/U
RG 142 B/U
RG 174 U
RG 174 A/U
RG 178 B/U
RG 179 B/U
RG 187 A/U
RG 188 A/U
RG 195 A/U
RG 196 A/U
RG 316 /U
CuSn
CuStAg
CuSt
CuSt
CuStAg
CuStAg
CuStAg
CuStAg
CuStAg
CuStAg
CuStAg
ScreenDielectric
Mat. ø mmMat. Stranding ø mm Mat. ø mm
Conductor Sheath
Mat. Colour ø mm kg/100m.
3.80
6.60
1.10
0.85
1.50
1.60
1.60
2.80
1.10
1.60
4.95
4.95
2.55
2.80
1.80
2.60
2.60
2.60
3.70
2.00
2.60
7 x 0.16
7 x 0.06
7 x 0.16
0.50
0.19
0.50
PE
PFA
PTFE
1.50
0.52
1.52
CuAg
CuSn
CuAg
CuAg
CuAg
1
st
: 1.95
2
nd
: 2.40
0.9
1
st
: 2.00
2
nd
: 2.50
PVC
PFA
FEP
grey
white
G02232D-60
K01152-07
421-099
Cu
CuAg
CuStAg
2.10
0.90
1.95
3.10
1.25
3.05
Electrical and general properties
MIL-C-17
RG 58 C/U
RG 142 B/U
RG 174 /U
RG 174 A/U
RG 178 B/U
RG 179 B/U
RG 187 A/U
RG 188 A/U
RG 195 A/U
RG 196 A/U
RG 316 /U
50.3.1
50.2.1
50.2.1
50.1.1
75.2.1
75.2.2
50.2.3
50.1.2
50.2.2
KX 15
KX 38
KX 3A
KX 21A
KX 22A
Capaci-
tance
Impe-
dance
Ohm pF/m
IEC
60096-2
CCTU
10-01A
LEMO
Part-No
CCX.50.RG5.8CU50N
CCX.50.RG1.42BU50M
CCX.50.RG1.74U25N
CCX.50.RG1.74AU27N
CCX.50.RG1.78BU18M
CCX.75.RG1.79BU26M
CCX.75.RG1.87AU26B
CCX.50.RG1.88AU24B
CCX.95.RG1.95AU37B
CCX.50.RG1.96AU20B
CCX.50.RG3.16BU26M
50±2
50±2
50±2
50±2
50±2
75±3
75±3
50±2
95±5
50±2
50±2
101
95
101
101
96
64
64
96
49
96
96
Atte -
nuation
23
12.8
35
31.5
48
33
33
33
17
48
33
Operating
voltage
1.90
1.50
2.50
1.50
0.70
1.20
1.20
1.20
1.50
0.70
1.20
U max. KV eff.
Temperature
°C
from to
db/100 m
at 100 MHz
Series
•
•
••
••
••
••
••
••
•
••
••
-25 +70
-70 +200
-40 +75
-25 +70
-90 +205
-90 +205
-50 +205
-50 +205
-90 +205
-50 +205
-90 +205
00 01
50±2
50±5
50±2
101
96
96
24
72
72
1.50
0.45
2.50
•
•
•
-40 +105
-45 +165
-40 +75
Non
standard
Non
standard
Standard
Standard
Weight
Huber+Suhner G02232D-60
Huber+Suhner K01152-07
Storm 421-099
LEMO
Cable
group
6
7
3
8
1
2
2
4
5
1
4
8
9
8