Characteristics
Value Standard Test
Contact retention force
Cable pull off force
1)
Connector pull off force
Endurance
Operating temperature
> 60 N IEC 69512-8 15a
> 100 N IEC 69512-9 17c
> 110 N IEC 69512-8 15f
> 1000
IEC 69512-5 9a
cycles
- 55°C + 230°C
Characteristics
Value Standard Method
Impedance
Operating voltage (50 Hz)
Test voltage (50 Hz)
Rated current
Contact resistance
Screen resistance
Insulating resistance
VSWR
50 Ω –
0.3 kV rms –
1.0 kV rms IEC 60512-2 4a
4 A IEC 60512-3 5a
< 6 m Ω IEC 60512-2 2a
< 3.5 m Ω
> 10
12
Ω IEC 60512-2 3a
see chart N°1 beside
Mechanical and climatical
Electrical
Technical Characteristics
Note:
1)
Depending on cable design
1N = 0.102 kg
Voltage Standing Wave Ratio
The VSWR (Voltage Standing Wave Ratio) is the value
representing the power reflected in a connection. In
most cases, the working frequency range is where
VSWR is ≤ 1.25.
Note: VSWR measured with a RG-174 A/U cable. According to IEC
60169-1-1 standard
M1
Cable assembly (page 53)
FFS.01.250.DLAE24
FFS.01.250.DLAE31
Part number
Cable Cond. Dielectric Ø Sheath Ø
group Ø max max max
1 0.55 0.95 2.35
2-3-4 0.55 1.65 3.0
M1
Cable assembly (page 53)
FFH.01.250.DLAE31
Part number
Cable Cond. Dielectric Ø Sheath Ø
group Ø max max max
2-3-4 0.55 1.65 3.0
1
1000 2000 3000 4000 5000 f
(MHz)
1.1
1.0
V
SWR
FFS + PCS
1.2
1.3
50Ω
S 4
13
ø 5
18
FFH Straight plug, non-latching