Terminating of elbow plugs (90°) with cable collet (solder contact) and cable crimp (solder contact)
M7M6
1. Cable preparation
First place the bend relief
(if to be used) on the cable.
Strip the cable according to
dimensions below.
2. Cable terminating
2.1 Place the collet nut and
collet on the cable. Fold
back the shield braid onto
the conical part of the collet,
and trim to outer edge of the
collet.
2.2 Slide the assembly into
the connector shell
and tighten the collet nut
using the appropriate tool
to a torque of 0.25 Nm
(see “Tooling” on page 35,
36 and 37). Check that
the cable conductor rests
in the contact slot, solder
the conductor through
the hole.
2.3 Place the insulating sleeve
over the soldered contact.
2.4 Close the access hole with
the flat screw .
Push the bend relief (if used)
onto the collet nut .
1. Cable preparation
First place the bend relief
(if to be used) on the cable.
Strip the cable according to
dimensions below.
2. Cable terminating
2.1 Place the cable crimp ferrule
on the cable and widen
the braiding.
2.2 Slide the cable into the con-
nector shell . Check that
cable conductor rests in the
contact slot, tin solder the
conductor through the hole.
Slide the crimp ferrule over
the braiding until it reaches
the connector shell . Crimp
with the LEMO crimp tool
using the hexagonal opening
(see “Tooling” on page 37).
2.3 Place the insulating sleeve
over the soldered contact.
2.4 Close the connector hole
with the flat screw .
Push the bend relief (if used)
onto the crimping tube .
Note: these terminating instruc-
tions apply to the following
models:
M6 = FLA
Note: these terminating instruc-
tions apply to the following
models:
M7 = FLS, FLV
Cable
group
1-2-3-4-8
6-7
M7
TS L
14.5 9
34.511
Cable
group
1-2-3-4-8
M6
TS L
13.56.5
Solder
Solder