Datasheet
39www.lemo.com
®
®
Cable assembly
Terminating of plugs and straight sockets with cable collet
M3M2M1
5
5
5
2
4
3
3
4
1
1
T
± 0.2
S
± 0.2
L
± 0.2
1. Cable preparation
First place the bend relief (if to be used) on the cable.
Strip the cable according to dimensions below.
2. Cable termination
2.1 Place the collet nut ➀ and the collet ➁ on the cable. Fold back the
shield braid onto the conical part of the collet, and trim to the outer
edge of the collet
2.2 Slide the subassembly ➂ to trap the shield braiding and solder the
central conductor into the contact.
Straight plug
Free socket
Fixed socket
nut fixing
Crimp
Crimp
2.3 Slide the insulator ➃ onto the subassembly ➂ until it rests against
the earthing sleeve of the subassembly ➂.
2.4 Slide the assembly into the connector outer shell ➄. Screw the
collet nut ➀ into the connector outer shell ➄ using the appropriate
tool and tighten to a torque of 0.25 Nm (see “Tooling” on page 35,
36 and 37). Push the bend relief (if used) onto the collet nut.
Cable
group
1-2-3-4-8
6-7
M1
TSL
44.59
–––
M2
TSL
–––
7.5 8.5 13
M3
TSL
558
–––
Note: these terminating instructions apply to the following models:
M1 = FFA, FFE, FFF, PCA, PSA
M2 = FFY
M3 = FFC