Datasheet

39www.lemo.com
®
®
Cable assembly
Terminating of plugs and straight sockets with cable collet
M3M2M1
5
5
5
2
4
3
3
4
1
1
T
± 0.2
S
± 0.2
L
± 0.2
1. Cable preparation
First place the bend relief (if to be used) on the cable.
Strip the cable according to dimensions below.
2. Cable termination
2.1 Place the collet nut and the collet on the cable. Fold back the
shield braid onto the conical part of the collet, and trim to the outer
edge of the collet
2.2 Slide the subassembly to trap the shield braiding and solder the
central conductor into the contact.
Straight plug
Free socket
Fixed socket
nut fixing
Crimp
Crimp
2.3 Slide the insulator onto the subassembly until it rests against
the earthing sleeve of the subassembly .
2.4 Slide the assembly into the connector outer shell . Screw the
collet nut into the connector outer shell using the appropriate
tool and tighten to a torque of 0.25 Nm (see “Tooling” on page 35,
36 and 37). Push the bend relief (if used) onto the collet nut.
Cable
group
1-2-3-4-8
6-7
M1
TSL
44.59
–––
M2
TSL
–––
7.5 8.5 13
M3
TSL
558
–––
Note: these terminating instructions apply to the following models:
M1 = FFA, FFE, FFF, PCA, PSA
M2 = FFY
M3 = FFC