Datasheet
22 www.lemo.com
®
®
ø11
4.7
3
2.5
2 maxi
18
ø8.7
ø 0.7
5.08
0.9 (4 x)
M7x0.5
S 6.3
S 9
3.8 mini
5.8 maxi
15
ø 13
M7x0.5
S 9
ø 8
1
HEP Fixed socket, nut fixing, watertight
for printed circuit (back panel mounting)
HGW Fixed socket, nut fixing, watertight
with rear sealing ring
Part number
HGW.00.250.NTLP
Weight
(g)
4.2
P1
Panel cut-out (page 38)
Part number
HEP.00.250.NTNP
Weight
(g)
7.4
17
8 maxi
ø 11
1.5
ø 10.2
M7x0.5
S 9
HGP Fixed socket, nut fixing,
watertight or vacuumtight
Part number
HGP.00.250.NTLP
HGP.00.250.NTLPV
Weight
(g)
4.2
4.2
P1
Panel cut-out (page 38)
P5
Panel cut-out (page 38)
Watertight or vacuumtight models
Mechanical and climatical
A range of sealed sockets and couplers allows the device on which they are fitted to reach a protection index of IP68 as
per IEC 60529 (unmated). They are fully compatible with plugs of the same series and are widely used for portable
radios, military, laboratory equipment, aviation, etc.
These models are identified by a letter «P» at the end of the reference for watertight model and by a «PV» for vacuum -
tight models. Epoxy resin or o-rings are used to seal these models.
Characteristics Value Standard
> 5000 cycles IEC 60512-5 test 9a
up to 95% at 60° C
- 20° C/+100° C
> 144h IEC 60512-6 test 11f
20/80/21 IEC 60068-1
< 10
-7
mbar.l.s
-1
IEC 60512-7 test 14b
60 bars IEC 60512-7 test 14d
Endurance
Humidity
Temperature range
Salt spray corrosion test
Climatical category
Leakage rate (He)
1)
Maximum
operating pressure
2)
Note:
1)
only for vacuumtight models.
2)
this value corresponds to
the maximum allowed pressure
difference for the assembled
socket.
Note: Non standard, on request only
P15
PCB drilling pattern
(page 38)