Datasheet

~30
S 10.5
ø 14
~22
FFA.2C Straight plug, cable collet
ø 18
M15 x 1
S 17
9.5
2 maxi
17 maxi
ø 19.2
S 13.8
FAA.2C Fixed plug, nut fixing, non-latching
ø 18
M15 x 1
S 17
2
5 maxi
15.6 maxi
ø 19.2
S 13.8
ERA.2C Fixed socket, nut fixing
28.4
ø 14
20.4
S 12
FFA.2C Straight plug, cable collet and nut for fitting
a bend relief
1)
Note: all dimensions are in millimetres.
Note:
1)
to order, add a «Z» at the end of the reference.
The bend relief must be ordered separately (see page 141).
ø 20
M15 x 1
3.5
M15 x 1
S 17
4.2 maxi
15.6 maxi
ø 19.2
S 13.5
ECP.2C Fixed socket with two nuts
(back panel mounting)
ø 20
M15 x 1
3.5
M15 x 1
S 17
4.2 maxi
12.5
3
ø 19.2
S 13.5
ECP.2C Fixed socket with two nuts, straight contact
for printed circuit (back panel mounting)
Panel cut-out (page 122) PCB drilling pattern (page 122)Panel cut-out (page 122)
Panel cut-out (page 122) Panel cut-out (page 122)
> 500 cycles IEC 60512-5 test 9a
up to 95% at 60° C
- 55° C + 250° C
> 144 h IEC 60512-6 test 11f
IP50 IEC 60529
55/175/21 IEC 60068-1
Technical Characteristics
Endurance
Humidity
Temperature range
Salt spray corrosion test
Protection index
Climatical category
Characteristics Value Standard
Note:
The various tests have been carried out with FFA and ERA connector pairs,
with chrome-plated brass shell and PEEK insulator.
Detailed electrical characteristics, as well as materials and treatment are
presented in the chapter Technical Characteristics on page 171.
Mechanical and Climatical
Metal housing models
117www.lemo.com
®®
Cable assembly (page 122) Cable assembly (page 122)