Datasheet

LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice.
100915/18
www.lem.com
Page 1/3
Current Transducer LTS 6-NP
For the electronic measurement of currents: DC, AC, pulsed,
mixed with galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
I
PN
Primary nominal current rms 6 At
I
PM
Primary current, measuring range 0 .. ± 19.2 At
Î
P
Overload capability 250 At
V
OUT
Output voltage (Analog) @ I
P
2.5
±
(0.625·I
P
/I
PN
) V
I
P
= 0 2.5
1)
V
G Sensitivity 104.16 mV/A
N
S
Number of secondary turns (± 0.1 %) 2000
R
L
Load resistance 2 kW
R
IM
Internal measuring resistance (± 0.5 %) 208.33 W
TCR
IM
Temperature coefcient of R
IM
< 50 ppm/K
V
C
Supply voltage (± 5 %) 5 V
I
C
Current consumption @ V
C
= 5 V Typ 28+I
S
2)
+(V
OUT
/R
L
) mA
X Accuracy @ I
PN
, T
A
= 25°C ± 0.2 %
Accuracy - Dynamic performance data
Accuracy with R
IM
@ I
PN
, T
A
= 25°C ± 0.7 %
ε
L
Linearity error < 0.1 %
Typ Max
TCV
OUT
Temperature coefcient of V
OUT
@ I
P
= 0 - 10°C .. + 85°C 80 200 ppm/K
- 40°C .. - 10°C 250 ppm/K
TCG
Temperature coefcient of G - 40°C .. + 85°C 50
3)
ppm/K
V
OM
Magnetic offset voltage @ I
P
= 0,
after an overload of 3 x I
PN
± 0.5 mV
5 x I
PN
± 2.0 mV
10 x I
PN
± 2.0 mV
t
ra
Reaction time @ 10 % of I
PN
< 100 ns
t
r
Response time to 90 % of I
PN
step < 400 ns
di/dt di/dt accurately followed > 15 A/µs
BW Frequency bandwidth (0 .. - 0.5 dB) DC .. 100 kHz
(- 0.5.. 1 dB) DC .. 200 kHz
General data
T
A
Ambient operating temperature - 40 .. + 85 °C
T
S
Ambient storage temperature - 40.. + 100 °C
m Mass 10 g
Standards EN 50178: 1997
IEC 60950-1: 2001
Notes:
1)
Absolute value @ T
A
= 25°C, 2.475 < V
OUT
< 2.525
2)
I
S
= I
P
/N
S
3)
Only due to TCR
IM
.
I
PN
= 6 At
Features
Closed loop (compensated) multi-
range current transducer using
the Hall effect
Unipolar voltage supply
Isolated plastic case recognized
according to UL 94-V0
Compact design for PCB
mounting
Incorporated measuring
resistance
Extended measuring range.
Advantages
Excellent accuracy
Very good linearity
Very low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and
servo motor drives
Static converters for DC motor
drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Application domain
Industrial.
16065

Summary of content (3 pages)