Datasheet

Page 1/3
060228/16
LEM Components www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Current Transducer LTS 15-NP
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
I
PN
Primary nominal r.m.s. current 15 At
I
P
Primary current, measuring range 0 .. ± 48 At
Î
PDC
Overload capability 250 At
V
OUT
Analog output voltage @ I
P
2.5
±
(0.625·I
P
/I
PN
)V
I
P
= 0 2.5
1)
V
N
S
Number of secondary turns (± 0.1 %) 2000
R
L
Load resistance 2 k
R
IM
Internal measuring resistance (± 0.5 %) 83.33
TCR
IM
Thermal drift of R
IM
< 50 ppm/K
V
C
Supply voltage (± 5 %) 5 V
I
C
Current consumption @ V
C
= 5 V Typ 28+
I
S
2)
+
(V
OUT
/R
L
)mA
Accuracy - Dynamic performance data
X Accuracy @ I
PN
, T
A
= 25°C ± 0.2 %
Accuracy with R
IM
@ I
PN
, T
A
= 25°C ± 0.7 %
ε
L
Linearity error < 0.1 %
Typ Max
TCV
OUT
Thermal drift of V
OUT
@ I
P
= 0 - 10°C .. + 85°C 65 120 ppm/K
- 40°C .. - 10°C 170 ppm/K
TCε
G
Thermal drift of the gain - 40°C .. + 85°C 50
3)
ppm/K
V
OM
Residual voltage
@ I
P
= 0, after an overload of 3 x I
PN
± 0.5 mV
5 x I
PN
± 2.0 mV
10 x I
PN
± 2.0 mV
t
ra
Reaction time @ 10 % of I
PN
< 100 ns
t
r
Response time @ 90 % of I
PN
< 400 ns
di/dt di/dt accurately followed > 35 A/µs
f Frequency bandwidth (0 .. - 0.5 dB) DC .. 100 kHz
(- 0.5 .. 1 dB) DC .. 200 kHz
General data
T
A
Ambient operating temperature - 40 .. + 85 °C
T
S
Ambient storage temperature - 40 .. + 100 °C
m Mass 10 g
Standards EN 50178 : 1997
IEC 60950-1 : 2001
Notes :
1)
Absolute value @ T
A
= 25°C, 2.475 < V
OUT
< 2.525
2)
I
S
= I
P
/N
S
3)
Only due to TCR
IM
.
Features
Closed loop (compensated) multi-
range current transducer using the
Hall effect
Unipolar voltage supply
Compact design for PCB mounting
Insulated plastic case recognized
according to UL 94-V0
Incorporated measuring resistance
Extended measuring range.
Advantages
Excellent accuracy
Very good linearity
Very low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Application domain
Industrial.
I
PN
=
15 At
Copyright protected.
16058

Summary of content (3 pages)