Datasheet

05July2011/version 11
LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice.
www.lem.com
Page 3/3
Connection
Dimensions LF 2005-S (in mm)
Mechanical characteristics
General tolerance ± 1 mm
Transducer fastening
Vertical or at position 4 holes Ø 6.5 mm
4 steel screws M6
Recommended fastening torque 5.5 Nm
Primary through-hole 60.5 x 20.5
or Ø max 57 mm
Connection of secondary S3P-VH
Remarks
I
S
is positive when I
P
ows in the direction of the arrow.
Temperature of the primary conductor should not exceed
100°C.
Dynamic performances (di/dt and response time) are best
with a single bar completely lling the primary hole.
This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.