Datasheet

Page 1/3
www.lem.com
071129/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Current Transducer LAH 100-P
For the electronic measurement of currents: DC, AC, pulsed ...,
with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
Electrical data
I
PN
Primary nominal current rms 100 A
I
PM
Primary current, measuring range
1)
0 .. 160 A
R
M
Measuring resistance @ T
A
= 70°C T
A
= 85°C
R
M min
R
M max
R
M min
R
M max
with ± 12 V @ I
PN
[± A
DC
] 0 63 0 57
@ I
PN
[A
RMS
]
2)
0 11 0 5
with ± 15 V @ I
PN
[± A
DC
] 20 120 45 114
@ I
PN
[A
RMS
]
2)
20 51 45 45
@ I
P
< I
PN
3)
I
SN
Secondary nominal current rms 50 mA
K
N
Conversion ratio 1 : 2000
V
C
Supply voltage (± 5 %) ± 12 .. 15 V
I
C
Current consumption 10 (@ ± 15V) + I
S
mA
Accuracy - Dynamic performance data
X Accuracy
4)
@ I
PN,
T
A
= 25°C ± 0.25 %
ε
L
Linearity error < 0.15 %
Typ Max
I
O
Offset current @ T
A
= 25°C ± 0.15 mA
I
OM
Magnetic offset current
@ I
P
= 0 and specified R
M
,
after an overload of 5 x I
PN
± 0.10 ± 0.15 mA
I
OT
Temperature variation of I
O
0°C .. + 70°C ± 0.10 ± 0.40 mA
- 25°C .. + 85°C ± 0.10 ± 0.50 mA
t
r a
Reaction time @ 10 % of I
PN
< 200 ns
t
r
Response time
5)
to 90 % of I
PN
step < 500 ns
di/dt di/dt accurately followed > 200 A/µs
BW Frequency bandwidth (- 1 dB) DC .. 200 kHz
General data
T
A
Ambient operating temperature - 25 .. + 85 °C
T
S
Ambient storage temperature - 40 .. + 90 °C
R
S
Secondary coil resistance @ T
A
= 70°C 115
@ T
A
= 85°C 121
m Mass 24 g
Standards EN 50178: 1997
Notes:
1)
For 10 s, with R
M
25 (V
C
= ± 15 V)
2)
50 Hz Sinusoidal
3)
The measuring resistance R
M min
may be lower
(see "LAH Technical Information" leaflet)
4)
Without I
O
& I
OM
5)
With a di/dt of 100 A/µs.
I
PN
=
100
A
16052
Features
Closed loop (compensated) current
transducer using the Hall effect
Printed circuit board mounting
Insulated plastic case recognized
according to UL 94-V0.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Application domain
Industrial.

Summary of content (3 pages)