Datasheet

Page 1/3
15June2015/version 16 LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice www.lem.com
N° 97.13.25.000.0
I
PN
= 50 A
Features
Closed loop (compensated)
current transducer using the Hall
effect
Insulating plastic case recognized
according to UL 94-V0.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and
servo motor drives
Static converters for DC motor
drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Application domain
Industrial.
Current Transducer LA 55-P
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic separation between the primary circuit and the secondary
circuit.
Electrical data
I
PN
Primary nominal rms current 50 A
I
PM
Primary current, measuring range 0 .. ±70 A
R
M
Measuring resistance @ T
A
= 70 °C T
A
= 85 °C
R
M min
R
M max
R
M min
R
M max
with ±12 V @ ±50 A
max
10 100 60 95
@ ±70 A
max
10 50 60
1)
60
1)
with ±15 V @ ±50 A
max
50 160 135 155
@ ±70 A
max
50 90 135
2)
135
2)
I
SN
Secondary nominal rms current 50 mA
K
N
Conversion ratio 1 : 1000
U
C
Supply voltage (±5 %) ±12 .. 15 V
I
C
Current consumption 10 (@ ±15 V) + I
S
mA
Accuracy - Dynamic performance data
X Accuracy @ I
PN
, T
A
= 25 °C @ ±15 V (±5 %) ±0.65 %
@ ±12 .. 15 V (±5 %) ±0.90 %
ε
L
Linearity error <0.15 %
Typ Max
I
O
Offset current @ I
P
= 0, T
A
= 25 °C ±0.2 mA
I
OM
Magnetic offset current
3)
@ I
P
= 0 and specied R
M
,
after an overload of 3 × I
PN
±0.3 mA
I
OT
Temperature variation of I
O
-25 °C .. +85 °C ±0.1 ±0.6 mA
-40 °C .. -25 °C ±0.2 ±1.0 mA
t
ra
Reaction time <500 ns
t
r
Step response time to 90 % of I
PN
<1 µs
di/dt di/dt accurately followed >200 A/µs
BW Frequency bandwidth (-1 dB) DC .. 200 kHz
General data
T
A
Ambient operating temperature -40 .. +85 °C
T
S
Ambient storage temperature -40 .. +90 °C
R
S
Resistance of secondary winding @ T
A
= 70 °C 80
 @ T
A
= 85 °C 85
m Mass 18 g
Standards EN 50178: 1997
UL 508: 2010
Notes:
1)
Measuring range limited to ±60 A
max
2)
Measuring range limited to ±55 A
max
3)
Result of the coercive eld of the magnetic circuit.

Summary of content (3 pages)