Datasheet

Current Transducer LA 35-NP
For the electronic measurement of currents : DC, AC, pulsed,
mixed, with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
Electrical data
I
PN
Primary nominal r.m.s. current 35
1)
At
I
P
Primary current, measuring range 0 .. ± 70 At
R
M
Measuring resistance R
M min
R
M max
with ± 15 V @ ± 35 At
max
60 150
@ ± 70 At
max
60 85
I
SN
Secondary nominal r.m.s. current 35 mA
K
N
Conversion ratio 1-2-3-4-5 : 1000
V
C
Supply voltage (± 5 %) ± 15 V
I
C
Current consumption 10 + I
S
mA
V
d
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn 2.5 kV
V
b
R.m.s. rated voltage
2)
, safe separation 600 V
basic isolation 1700 V
Accuracy - Dynamic performance data
X Typical accuracy @ I
PN,
T
A
= 25°C ± 0.5 %
ε
L
Linearity < 0.2 %
Typ Max
I
O
Offset current
3)
@ I
P
= 0, T
A
= 25°C ± 0.10 ± 0.20 mA
I
OM
Residual current
4)
@ I
P
= 0, after an overload of 3 x I
PN
± 0.05 ± 0.15 mA
I
OT
Thermal drift of I
O
- 25°C .. + 70°C ± 0.15 ± 0.50 mA
t
r
Response time
5)
@ 90 % of I
PN
< 1 µs
di/dt di/dt accurately followed > 50 A/µs
f Frequency bandwidth (- 1 dB) DC .. 150 kHz
General data
T
A
Ambient operating temperature - 25 .. + 70 °C
T
S
Ambient storage temperature - 40 .. + 85 °C
R
P
Primary resistance per turn @ T
A
= 25°C < 1.25 m
R
S
Secondary coil resistance @ T
A
= 70°C 80
R
IS
Isolation resistance @ 500 V, T
A
= 25°C > 1500 M
m Mass 22 g
Standards EN 50178 : 1997
Notes :
1)
In order to avoid over-heating, it is necessary that the recommended
primary connections be followed (see table page 2).
2)
Pollution class 2
3)
Measurement carried out after 15 mn functioning
4)
The result of the coercive field of the magnetic circuit
5)
With a di/dt of 100 A/µs.
Features
Closed loop (compensated) multi-
range current transducer using the
Hall effect
Printed circuit board mounting
Insulated plastic case recognized
according to UL 94-V0.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
060719/4
I
PN
=
7-8-11-17-35
A
LEM Components www.lem.com
16136

Summary of content (2 pages)