Datasheet
LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice.
www.lem.com
Page 3/3
090508/15
Connection
Dimensions LA 200-P (in mm. 1 mm = 0.0394 inch)
Front view
Bottom view Left view
Mechanical characteristics
General tolerance ± 0.2 mm ●
Primary through-hole 17 x 11 mm ●
Fastening & connection of secondary 4 pins ●
0.63 x 0.56 mm
Recommended PCB hole 0.9 mm ●
Supplementary fastening 2 holes Ø 1.75 mm ●
Recommended PCB hole 2.4 mm
Recommended screws PT KA 22 x 6.
Remarks
I ●
S
is positive when I
P
ows in the direction of the arrow.
Temperature of the primary conductor should not exceed ●
90°C.
Dynamic performances (di/dt and response time) are best ●
with a primary bar in low position in the through-hole.
In order to achieve the best magnetic coupling, the ●
primary windings have to be wound over the top edge of
the device.
This is a standard model. For different versions (supply ●
voltages, turns ratios, unidirectional measurements...),
please contact us.