Datasheet

LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice.
www.lem.com
Page 1/3
090616/8
I
PN
= 100 A
Features
Closed loop (compensated) ●
current transducer using the Hall
effect
Printed circuit board mounting ●
Insulated plastic case recognized ●
according to UL 94-V0.
Advantages
Excellent accuracy ●
Very good linearity ●
Low temperature drift ●
Optimized response time ●
Wide frequency bandwidth ●
No insertion losses ●
High immunity to external ●
interference
Current overload capability. ●
Applications
AC variable speed drives and ●
servo motor drives
Static converters for DC motor ●
drives
Battery supplied applications ●
Uninterruptible Power Supplies ●
(UPS)
Switched Mode Power Supplies ●
(SMPS)
Power supplies for welding ●
applications.
Application domain
Industrial. ●
Current Transducer LA 100-TP
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
I
PN
Primary nominal current rms 100 A
I
PM
Primary current, measuring range 0 .. ± 150 A
R
M
Measuring resistance @ T
A
= 70°C T
A
= 85°C
R
M min
R
M max
R
M min
R
M max
with ± 12 V @ ± 100 A
max
0 50 0 42 Ω
@ ± 120 A
max
0 22 0 14 Ω
with ± 15 V @ ± 100 A
max
0 110 20 102 Ω
@ ± 150 A
max
0 33 20 25 Ω
I
SN
Secondary nominal current rms 50 mA
K
N
Conversion ratio 1 : 2000
V
C
Supply voltage (± 5 %) ± 12 .. 15 V
I
C
Current consumption 10 (@ ± 15 V) + I
S
mA
X Accuracy @ I
PN
, T
A
= 25°C @ ± 15 V (± 5 %) ± 0.45 %
Accuracy - Dynamic performance data
@ ± 12 .. 15 V (± 5 %) ± 0.70 %
ε
L
Linearity error < 0.15 %
Typ Max
I
O
Offset current @ I
P
= 0, T
A
= 25°C ± 0.10 mA
I
OM
Magnetic offset current
1)
@ I
P
= 0 and specied R
M
,
after an overload of 3 x I
PN
± 0.15 mA
I
OT
Temperature variation of I
O
- 25°C .. + 85°C ± 0.05 ± 0.30 mA
- 40°C .. - 25°C ± 0.10 ± 0.50 mA
t
ra
Reaction time to 10 % of I
PN
step < 500 ns
t
r
Response time
2)
to 90 % of I
PN
step < 1 µs
di/dt di/dt accurately followed > 200 A/µs
BW Frequency bandwidth (- 1 dB) DC .. 200 kHz
T
A
Ambient operating temperature - 40 .. + 85 °C
General data
T
S
Ambient storage temperature - 40 .. + 90 °C
R
S
Secondary coil resistance @ T
A
= 70°C 120 Ω
@ T
A
= 85°C 128 Ω
m Mass 24 g
Standards
3)
EN 50178
Notes:
1)
Result of the coercive eld of the magnetic circuit
2)
With a di/dt of 100 A/µs
3)
A list of corresponding tests is available.
16045