Datasheet

Electrical data
Primary nominal Primary current, Primary conductor Type RoHS since
current rms measuring range
1)
diameter x turns date code
I
PN
(A) I
PM
(A) (mm)
3 ± 9 0.6d x 20T HX 03-P/SP2 46128
5 ± 15 0.8d x 12T HX 05-P/SP2 46019
10 ± 30 1.1d x 6T HX 10-P/SP2 45352
15 ± 45 1.4d x 4T HX 15-P/SP2 46133
20 ± 60 1.6d x 3T HX 20-P/SP2 planned
25 ± 75 1.6d x 2T HX 25-P/SP2 46233
50 ± 150 1.2 x 6.3 x 1T HX 50-P/SP2 46152
V
OUT
Output voltage (Analog) @ ± I
PN
, R
L
= 2 k, T
A
= 25°C V
OE
± 0.625 V
R
OUT
Output internal resistance < 50
R
L
Load resistance 2 k
V
C
Supply voltage (± 5 %) + 12 .. 15 V
I
C
Current consumption < 15 mA
V
d
Rms voltage for AC isolation test, 50 Hz, 1 min > 3 kV
V
e
Partial discharge extinction voltage rms @ 10 pC 1 kV
V
W
Impulse withstand voltage, 1.2/50 µs 6 kV
Accuracy-Dynamic performance data
X Accuracy @ I
PN
, T
A
= 25°C (excluding offset) < ± 1 % of I
PN
ε
L
Linearity error (0 .. ± I
PN
) < ± 1 % of I
PN
V
OE
Electrical offset voltage @ T
A
= 25°C + 2.5V ± 50 mV
V
OH
Hysteresis offset voltage @ I
P
= 0;
after an excursion of 1 x I
PN
< ± 10 mV
TCV
OE
Temperature coefficient of V
OE
< ± 1.5 mV/K
TCV
OUT
Temperature coefficient of V
OUT
(% of reading) ± 0.1 %/K
t
r
Response time to 90% of I
PN
step 3 µs
BW Frequency bandwidth (- 3 dB)
2)
50 kHz
General data
T
A
Ambient operating temperature - 25 .. + 85 °C
T
S
Ambient storage temperature - 25 .. + 85 °C
m Mass 8 g
dCp Creepage distance 5.5 mm
Isolation material group I
Standards EN50178: 1997
Current Transducer HX 03..50-P/SP2
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
I
PN
= 3 .. 50 A
Notes :
1)
With R
L
=2k
2)
Small signal only to avoid excessive heating of the magnetic core
Features
Galvanic isolation between primary
and secondary circuit
Hall effect measuring principle
Isolation voltage 3000V
Low power consumption
Extended measuring range(3x I
PN
)
Isolated plastic case recognized
according to UL94-V0.
Special feature
Single supply from +12V to +15V
Advantages
Low insertion losses
Easy to mount with automatic
handling system
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Applications
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Electrical appliances
Battery supplied applications
DC motor drives
Application domain
Industrial
070313/6 www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/2

Summary of content (2 pages)