Datasheet
Electrical data
Primary nominal Primary current Type
r.m.s. current measuring range
I
PN
(A) I
P
(A)
50 ±150 HTB 50-P/SP5, HTB 50-TP/SP5
1)
100 ±300 HTB 100-P/SP5, HTB 100-TP/SP5
1)
200 ±500 HTB 200-P/SP5
300 ±600 HTB 300-P/SP5
400 ±600 HTB 400-P/SP5
V
C
Supply voltage (±5 %)
2)
+12 .. +15 V
I
C
Current consumption <15 mA
V
d
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn 2.5 kV
R
IS
Isolation resistance @ 500 VDC >500 MΩ
V
OUT
Output voltage @ ± I
PN
, R
L
= 10 kΩ, T
A
= 25°C V
OE
±1.667 V
R
OUT
Output internal resistance 100 Ω
R
L
Load resistance ≥10 kΩ
Accuracy - Dynamic performance data
X Accuracy @ I
PN
, T
A
= 25°C (without offset) <±1 % of I
PN
εε
L
Linearity (0 .. ± I
PN
) <±1 % of I
PN
V
OE
Electrical offset voltage, T
A
= 25°C Vc/2±30 mV
V
OH
Hysteresis offset voltage @ I
P
= 0;
after an excursion of 3 x I
PN
<±0.5 % of I
PN
V
OT
Thermal drift of V
OE
HTB 50-(T)P/SP5 <±1.0 mV/K
HTB 100-(T)P..400-P/SP5 <±0.5 mV/K
TCεε
G
Thermal drift (% of reading) <±0.05 %/K
t
r
Response time @ 90% of I
P
<3 µs
f Frequency bandwidth (-3 dB)
3)
DC .. 50 kHz
General data
T
A
Ambient operating temperature -25 .. +85 °C
T
S
Ambient storage temperature -25 .. +85 °C
m Mass (-TP version) <30 (<36) g
I
PN
= 50 .. 400 A
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2500V
• Low power consumption
• Primary bus bar option for 50A and
100A version for ease of connection
Special Features
• Single power supply from 12V to 15V
Advantages
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
interference.
Applications
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
LEM Components www.lem.com
030221/0
Current Transducers HTB 50 .. 400-P/SP5
and HTB 50 .. 100-TP/SP5
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Notes : EN 50178 approval pending
1)
-TP version is equipped with a primary bus bar.
2)
Operating at +12V ≤ Vc < +15V will reduce measuring range.
3)
Derating is needed to avoid excessive core heating at high frequency.