Datasheet
Current Transducer AHR-B10
Isolation characteristics
V
b
Rated isolation voltage rms
3)
500 V
with IEC 61010-1 according to the 61326 standards and following conditions:
- Reinforced isolation
- Over voltage category III
- Pollution degree PD2
- Heterogeneous field
V
d
Rms voltage for AC isolation test
4)
, 50 Hz, 1min 5.8 kV
dCp Creepage distance 11.9 mm
dCl Clearance distance 11.9 mm
CTI Comparative tracking index (Group I) 250-399
Notes :
3)
If insulated cable is used for the primary circuit, the voltage category could
be improved according to the insulation characteristics given by the cable
manufacturer.
4)
Between primary (completely filling the aperture) and secondary.
Output polarity with DC input
Output in V
10
0
+Ipn-Ipn
080116/7 www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 2/4