Operator's Manual

5.1701.8500.0 -
Installation 6-11
9. Connect the cables to the camera with the M12 torque tool.
Ethernet (required) marked as ETH.
Power supply marked as PWR.
1. Required in case of (and / or).
No use of PoE switch / injector.
CAN port in use.
DIO as output.
CAN port (optional).
1. In case of heifer monitoring, a tag reader is required.
GPIO peripherals (optional).
IP 65 compliance
Los of IP 65 rating/compliance.
Place sealing caps on the connectors which are not in use.
10. Check the functionality of the Lely Calm View and peripherals before installation.
11. Unplug the power of the Lely Calm View on the not-device side. When PoE is used unplug the Ethernet
on the not-device side.
12. Align adapter plate in such a way that the Lely Calm View is aligned as described per situation (see
Determine placement of the camera on page 6-3).
13. Slide the bracket with the Lely Calm View over the horizontal bar, up to the required position.
Use a double sided ladder when installing the horizontal bar for heifers.
in n o vato rs in agriculture