Completely unwind the power supply cord. Should the power cord be damaged, please let only
authorized, technically qualied people replace it.
The coffee machine should sit on a at, stable surface at least 20 mm from walls and from the
counter. Keep in mind that the highest surface on the machine (the cup warmer) should sit at a height
of at least 1.2 meters. Make sure there is a shelf nearby for the accessories.
Room temperature must range between 10° and 32°C (50°F and 90°F).
An electrical outlet, plumbing connections and a drain with siphon must be in the immediate vicinity.
Do not install in rooms (kitchens) that are cleaned with jets of water.
Do not obstruct openings or ventilation and heat vents.
Do not install the machine outdoors.
3. Electrical installation
Prior to installation, make sure there is a circuit breaker installed with a distance between the contacts
that allows for complete disconnection when there is a category III overload and that provides
protection against current leakage equal to 30 mA. The circuit breaker must be installed on the power
supply in compliance with installation rules. If the power supply is not working properly, the machine
can cause transitory voltage drops.
The electrical safety of this machine is only ensured when it is correctly connected to an efcient
earthing system in compliance with the electrical safety laws in force. This fundamental safety
requirement must be veried. If in doubt, require that a qualied electrician inspects the system. The
manufacturer cannot be held responsible for any damage caused by the lack of an earthing system
on the electrical supply.
It is unadvisable to use adaptors, multiple plugs, and/or extension cords. If their use is indispensable,
only use simple or multiple adaptor plugs and extension cords that are in compliance with safety laws.
Make sure that these devices do not exceed the voltage capacity marked on the simple adaptor and
on extension cords, and the maximum voltage marked on the multiple adaptor.
Check that the type of connection and voltage correspond with the information on the technical data label.
4. Equipotential connection
4.1
1
This type of connection, required by some laws, prevents
differences in the electric potential level between the earthing
connections of equipment installed in the same room. This
machine is provided with a clamp (1) UNDERNEATH THE
BASE for the connection of an external equipotential
conductor. After installation, this type of connection MUST be
made (Pic. 4.1).
Use a conductor with a nominal section in compliance with
the laws in force.
Connect one end of the conductor to the clamp and the other
end to the earthing of adjacent equipment.
Failure to follow this safety norm releases the manufacturer from any responsibility for machine
breakdowns or damage to people or property.
Attention. Do not connect to the power supply earthing because it is not considered an equipotential
cable connection. Bear in mind that Gemme Italian Producers srl is not responsible for damage caused by
improper electrical connections, and that the installer is responsible for any damage.