User Manual
English
11
EN
The access to the service area is restricted to persons having knowledge and practical experience of
the appliance, in particular as far as safety and hygiene are concerned.
Cleaning and user maintenance shall not be made by children without supervision.
11. Turning the machine ON
Attention. Before setting the machine at work, make sure that: the main electric power switch
is on and that main water tap is open.
ON
OFF
11.1
4
ELECTRIC SWITCH ON
Press the main switch (4) ON (Pic. 11.1). The boiler will be
lled with water until the foreseen level. The “Heating phase”
will start. At the end of the working day, the machine can go
into the Stand by mode (automatically after 240 minutes of
inactivity) or can be turned off by pressing the main switch
(4) OFF.
12. Warming up phase
Attention. Do not put any cloth on the cup warmer..
While waiting for the machine to get ready, x the lterholders (9) in the extraction groups. Do not
cover the cup warmer with cloths to prevent the over-heating of the machine. When the display shows
the exercise temperature, the machine is ready for use.
13. Coffee extraction
K1 K2 K3 K4 K5
13.1
1. Unhook the lterholder (9) from the extraction group.
2. Fill the lter with the desired dose of ground coffee.
3. Press the coffee with a tamper and clean the lter edges from eventual coffee residues/rests.
4. Firmly lock the lterholder (9) to the grouphead and make sure that the group gasket provides a good seal.
5. Place the cup/cups under the lterholder dispensing spouts.
6. PRE-PROGRAMMED DOSES: press one of the switches (K1-K2-K3-K4) and the pre-programmed
dose will be dispensed. Water will stop owing out once the programmed quantity will be reached.
7. CONTINUOUS DISPENSING: to have continuous dispensing, press the continuous/stop switch
K5 (Pic. 13.1).
8. Attention: if the machine is dispensing coffee and you press any of the switches of the same
selection panel, the dose will be interrupted.
9. To brew other coffees, remove the lterholder, clean it from the coffee rests with a wet soft cloth
and repeat the above mentioned operations.