7.11.5 With the cable retention bracket in position, set the enclosure down on the tray and loosely
install the common mounting screw from underneath to hold the retention bracket. Continue to
loosely install the remaining two screws. Do not overtighten as the unit needs to float within the
holes until step 6 of the V3ISU installation procedure.
Figure 25 – V3ISU Installation: Step 5
7.11.6 Apply pressure evenly to the front of the V3ISU to position the unit as far back and as far down
as possible within the mounting tray. The two outermost mounting points will provide the limit of
how far the unit will go in this direction. This is necessary to facilitate proper cable retention in
the rear and also to provide sufficient clearance for closing the tray. While holding the V3ISU in
this position, tighten the hardware to secure the unit within the tray.