5. Operation
5.3.1 Display of the program list
A maximum of 20 programs, each with up to
12 reagent steps and three paran processing
steps, can be dened.
At supervisor access level:
• Theprogramnamesfortheinfiltration
programs can be edited.
• Newinltrationprogramscanbeaddedand
existing ones can be deleted.
Fig. 152
The VIEW/EDIT USER PROGRAMS window (Fig. 152) displays a list of all freely
editable programs currently dened in the ASP6025.
Program duration cannot be specied. It is determined by the total duration of all program steps,
plus the estimated ll and drain times. To alter the duration of a program, the duration of one or
more individual program steps has to be modied.
5.3 Inltration programs
New inltration programs are created by copying an existing program and then
modifying it accordingly. Therefore, the list must contain at least one program
at all times.
The retort cleaning programs are also preset.