Manual

109
Leica ASP6025
5. Operation
5.3.1 Display of the program list
A maximum of 20 programs, each with up to
12 reagent steps and three paran processing
steps, can be dened.
At supervisor access level:
 Theprogramnamesfortheinfiltration
programs can be edited.
• Newinltrationprogramscanbeaddedand
existing ones can be deleted.
Fig. 152
The VIEW/EDIT USER PROGRAMS window (Fig. 152) displays a list of all freely
editable programs currently dened in the ASP6025.
Program duration cannot be specied. It is determined by the total duration of all program steps,
plus the estimated ll and drain times. To alter the duration of a program, the duration of one or
more individual program steps has to be modied.
5.3 Inltration programs
New inltration programs are created by copying an existing program and then
modifying it accordingly. Therefore, the list must contain at least one program
at all times.
The retort cleaning programs are also preset.
They cannot be renamed, added, modied or deleted.