User Manual

Page 61
301 Fulling Mill Road, Suite G ©Copyright 2012 by Legrand,
Middletown, PA 17057 Inc All Rights Reserved.
(800)-321-2343 www.onqlegrand.com
Figure 4-31 SNMP Settings
SNMP Agent - Select the radio button before Enable to enable this function if you want to have
remote control through SNMPv1/v2 agent with MIB-II. Select the radio button before Disable to
disable this function. The default setting is Disable.
SysContact - The textual identification of the contact person for this managed node.
SysName - An administratively-assigned name for this managed node.
SysLocation - The physical location of this node.
Note: Specifying one of these values via the Device's Web-Based Utility makes the
corresponding object read-only. If there isn't such a config setting, then the write request will
succeed (assuming suitable access control settings), but the new value would be forgotten the
next time the agent was restarted.
Get Community - Enter the community name that allows Read-Only access to the Device's
SNMP information. The community name can be considered a group password. The default
setting is “public”.
Get Source - Get source defines the IP address or subnet for management systems that can read
information from this 'get' community device.
Set Community - Enter the community name that allows Read/Write access to the Device's
SNMP information. The community name can be considered a group password. The default
setting is “private”.
Set Source - Set source defines the IP address or subnet for management systems that can
control this 'set' community device.