TRIMOD HE MODULAR HIGH EFFICIENCY UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
TRIMOD HE DEVELOPMENTS IN TECHNOLOGY HIGH performance HIGH efficiency LOW environmental impact Legrand’s modular UPS know-how goes back more than 20 years, when the first ever modular UPS were introduced in 1993. Since then, continuous firmware development and research on control and hardware components have led to no stop improvements in system reliability, quality and technical performance.
® 1 kVA = kW POWER FACTOR WWW.UPS.LEGRAND.COM INCREASED POWER Thanks to their unity power factor the new TRIMOD HE UPS guarantee maximum real power; 11% more than competitor products offering 0,9 power factor, fully 25% more than those of 0.8 power factor.
TRIMOD HE HIGH DENSITY UPS In addition to the standard size, TRIMOD HE offers taller cabinets which allow increased autonomy as a standard configurations. Yet another enhancement to the range that increase performance while occupying the same amount of floor space. Enhanced version with the same footprint The new cabinets are taller but take up the same space in terms of footprint. 0.
® NEW CABINETS more new ADVANTAGES SOLUTIONS MORE redundancy and scalability TRIMOD HE TRIMOD HE Redundancy on overall power or within each individual phase. Power scalability (versions with internal batteries): for versions from 10 kVA to 20 kVA for versions from 15 kVA to 30 kVA up to 30 kVA MORE autonomy TRIMOD HE TRIMOD Optimising the number of cabinets for longer uptime of the 10-15-20 kVA versions.
TRIMOD HE EXPANDABLE SCALABLE MODULAR VERSATILE The innovative concept of THREE-PHASE modularity, consisting of INDIVIDUAL SINGLE-PHASE MODULES which feature in the entire TRIMOD HE range, allows you to optimise power availability, increase system flexibility and reduce the total cost of ownership (TCO). The standardised structure, consisting of smaller and lighter modules, makes it easier to transport and install the UPS systems.
® HIGH LEVELS of REDUNDANCY Thanks to the construction technology of the TRIMOD HE UPS systems, you can set various redundancy levels so that maximum continuity of service is always guaranteed. Redundancy on single-phase load R In a system with a threephase power supply and a single-phase load there will be no power loss if one of the modules fails, as the power will be delivered by the other operational modules.
TRIMOD HE Double conversion VFI three-phase modular UPS Pack POWER CABINET Cat. Nos. NOMINAL POWER kVA OPERATING TIME (MIN.) NO. OF INSTALLABLE BATTERY DRAWERS WEIGHT (kg) 10 10 15 15 20 20 30 30 40 60 0' 0' 0' 0' 0' 0' 0' 0' 0' 0' 12 16 12 16 12 16 12 - 120 155 120 155 120 155 146 181 146 165 3 103 96 3 103 97 3 104 08 3 104 03 3 104 14 3 104 09 3 104 18 3 104 15 3 104 19 3 104 20 3 108 71 POWER CABINETS (EMPTY) 3 108 43 3 104 42 Pack Cat. Nos.
® TRIMOD HE Double conversion VFI three-phase modular UPS 3 103 96 3 103 97 3 104 03 3 104 08 3 104 09 3 104 14 3 104 15* 3 104 18* 3 104 19 3 104 20 Nominal power (kVA) 10 15 20 30 40 60 Active power (kW) 10 15 20 30 40 60 Module power (kVA) 3.4 5 6.7 5 6.7 6.
Customer services 10 Reliable Excellent Tailor-made Directly present in more than 70 countries and servicing its products in more than 150 countries worldwide, a team of qualified engineers is available 24/7/365 to support your UPS system to ensure power quality and availability to the most critical loads. Legrand’s competitive edge lies in its ability to provide high value-added UPS systems and services for both end users and business partners.
® Support SITE INSPECTION, INSTALLATION SUPERVISION. We perform a comprehensive check of the UPS environment to ensure safety and fault-free operation. Our technical experts give manufacturer’s recommendations to the site engineer or electrical contractors, and supervise the UPS installation before load power-up. SITE TEST, COMMISSIONING. Our Service Engineers conduct rigorous site tests and full settingup of the UPS system before going live.
In accordance with its policy of continuous improvement, the Company reserves the right to change specifications and designs without notice. All illustrations, descriptions, dimensions and weights in this catalogue are given as a guide only.