Specification Sheet

SF20278 — Updated December 2018 — For latest specs visit www.legrand.us
Reinventing Safety All Around
1597, 2097, 1597TR, 2097TR, 1597TRWR, 2097TRWR
The radiant
®
Self-Test GFCI receptacle with SafeLock
®
Protection conducts an automatic test every three seconds,
ensuring it’s always ready to protect. If the device fails the test,
the indicator light flashes to signal that the GFCI should be
replaced. It also has our proven SafeLock Protection feature: if
critical components are damaged and protection is lost, power
to the receptacle is disconnected.
3rd Party Compliance
PASS & SEYMOUR
®
radiant
®
Specification Grade Self-Test GFCIs
15 & 20A, 125VAC
cULus Listed File Number E42190, Standard UL498 Attachment Plugs and Receptacles, UL943 GFCIs.
Federal Specification WC596, Hospital Grade. Standard CSA C22.2 No. 42 General Use Receptacles,
CSA C22.2 No. 144 GFCIs. Conforms to NEMA WD-1 and WD-6. RoHS compliant.
Features & Benefits
2097TRW
Meets latest UL Requirements
Prevents line-load reversal miswire:
No power to the face or downstream
receptacles if wired incorrectly.
High-impact-resistant, thermoplastic
construction for superior strength and durability.
Auto-ground clip assures a positive
ground to metal box.
Ground terminal clamp allows for
fast installation.
Patented SafeLock
®
Protection:
if critical components are damaged and
ground fault protection is lost, power to
the receptacle is disconnected.
The indicator light flashes if the device
fails the self-test, signalling that the
GFCI should be replaced.
Enhanced tamper-resistant
automatic shutter system allows for
easier plug insertion while preventing
young children from inserting com-
mon household objects.
Captive screws make for
easier installation.
New external back wire pressure
plates with posted terminal screws
for faster installation.
Redesigned side wire cavity improves
speed of side wire installation.
Now with black “invisi-shutters”
for an invisible effect preferred by
end users