Use and Care Manual

Left wheel equipped with the axle lock pin can be completely
released by removing the pin and installing it in the outer axle
hole. Unlock the left wheel to allow for easier turning of the unit.
To unlock the left wheel, remove the pin from the inner hole and
insert the axle pin through the outer axle hole, but not through the
wheel hub.
To lock the left wheel, insert the pin through the wheel hub and
the inner axle hole.
The engine is equipped with 120V A.C. electric starter and a recoil
starter. The electric starter is equipped with a three-way power
plug, and is designed to operate at the voltage shown in the label.
Before starting the engine, check engine oil level and
ensure the engine is served as described in the Engine
Manual with the snow blower.
To prevent damaging the electric GB starter, do not
run it more than 5 continuous seconds each time you
try to start. Wait 10 seconds between each attempt.
Do not use the electric starter if your household
voltage different from the one shown on the electric
starter.
1. Be sure fuel shutoff valve is in the OPEN position.
2. Move choke control to CLOSED position.
3. Insert safety ignition key into ignition slot until it clicks. Do not
turn the key.
4. Place RUN / STOP switch in RUN position.
5. Push the primer 2 or 3 times. When temperature is below 15
o
F
(-25
o
C), additional priming may be needed. When temperature
is above 50
o
F (10
o
C), priming is not necessary.
Over priming may cause ooding, preventing the
engine from starting. If you do ood the engine, wait
a few minutes before attempting to start and do not
push the primer.
Some snow engines are not equipped with a primer
bulb, as priming is not required to start the machine.
6. Connect an extension cord (not provided) to the engine by
plugging it into the three-way power plug.
7. Plug the other end of the extension cord into a three-wire
grounded receptacle.
8. Push starter button until engine starts.
9. When the engine starts, release the starter button and slowly
move the choke control to the OPEN position.
10. Disconnect the extension cord from the receptacle rst, then
from the engine.
STARTING AND STOPPING THE ENGINE
COLD START - ELECTRIC STARTER (120V AC)
OPERATION
FREEWHEELING AND SELF-PROPELLING
Figure 13a
Figure 13b
17
|
Operation