Operation Manual

18
1 Connect the signal cable to monitor, then turn on computer.
2. Connect the USB cable with monitor and computer.
3. Turn on the monitor (AC switch on).
4. Connect one side of USB cable (Type-B USB connector) on the
monitor side. See below picture. (Check “Connection” section
for exact location).
5. Connect the other side of USB cable (Type-A USB) to the USB
port on computer.
6. Wait for 5 seconds and the touch function is ready to go.
It can be activated by pen, fi nger, or any other pointer.
7. This touch monitor is Microsoft Windows 7 compatible. In order
to activate, go to
http://www.nextwindow.com/nextwindow_support/windriver.html
to download the latest driver.
Follow the direction in the NW Multitouch Device Driver
Installation Guide (part of the compressed fi le along with
the driver) to install the driver.
8. Once the driver is installed, restart the PC and the touch
function is ready to go with MS Windows 7.
9. Operating Systems Supported:
I. Microsoft Windows:
i. Windows 2000, XP, Vista, and 7: Plug-and-play
ii. Driver required to run dual-touch/gesture on
Windows 7 (works as a digitizer)
II. Mac OS: Plug-and-Play, Single touch only.
III. Linux: Supports Knoppix (based on Debian) distribution
with the following requirements:
i. Linux 2.6 kernel series
ii. Evtouch Touchscreen Driver
http://www.conan.de/touchscreen/evtouch.html
iii. Single touch only
10. 4-Point Calibration Procedure: (Note: no calibration is
required for fi rst time use, however, the touch panel might
be required for calibration over time depends on the usage)
I. Press the CAL button located next to the
USB connector (see page
8, item 4 for location) or press
the “Scroll Lock” key on the keyboard 6 times.
II. Wait for the beep sound, and the cursor will move to
near the upper left corner of the display automatically.
III. Place nger, gloved hand, or any other pointer on the
cursor, and stay for 2 seconds (a beep sound will occur
when the pointer is placed on the cursor). Then the cursor
will move to near the upper right corner automatically.
IV. Repeat the procedure of item III until all 4 points is
calibrated. (see image below for the places where
cursor appears).
V. Confi rm by tapping anywhere between the 4 points.
The calibration is completed and the touch monitor
is ready to be used now.
1. 2.
3.4.
8 Touch Operation