Operation Manual
17
System Status Menu
This read-only menu provides information on the active sources
and the latest fi rmware version.
1. When using VGA as signal source, go to Advanced Settings in
OSD menu and select VGA ADC Settings, then choose User ADC
Calibration.
2. A warning message (see image below) will show to make sure
proper image is displayed on screen before ADC calibration begins
I. Image in the green boxes, displayed on both side of the
screen, has to be white and black in order to run the
calibration accurately (the black and white image can
be made using software like Microsoft PowerPoint)
II. The white in the left green box has to be the
brightest white.
III. The black in the right green box has to be the
darkest black.
3. After proper image is displayed, click “Yes” to begin ADC
calibration
4. During calibration process, the following image will show
to notify user to wait for the calibration.
User ADC Calibration... Please Wait!
5. After calibration is completed, the display will notify user if the
process is done successfully by different messages.
User ADC Calibration Finish!
User ADC Calibration Failure!
Item Default Value
Power switch Off
Brightness 50
Backlight 80
Contrast 50
Color Temp. 9300 K
Source Auto Detection Off
OSD Language English
Auto Off
Monitor ID 01
IRFM Off
Baud rate115200
7 Default Setting
Region 1
(White)
Region 2
(Black)
Important Note:
1. The „Region 1“ must be all white.
2. The „Region 2“ must be all black.
Ready to run ADC Calibration?
Yes No