INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS M1-1020 (MK 2142) HAND SHOWER WITH BLACK HANDLE
Contents Dimensions 3 Warning Information 4 InstalLation Procedure 5 Parts List 6 Fault Finder 7 Safety Tips, Care and Maintenance 8 Guarantee 9 2
4 1/8" (104.9mm) 8 1/4" (209.2mm) (Ø76.5 mm) in Inches (& Millimetres) Ø3" Dimensions 1/2-14NPSM 3 9/16" (90.8mm) Whilst every effort is made to ensure accuracy, design and dimensions are subject to change without notice as part of the company’s product development process.
Warning (IMPORTANT INFORMATION) WARNING: Please ensure that the wall outlet of any installation with a hand shower is placed high enough on the wall, so that when fully assembled (outlet, hose & hand shower) it cannot reach the floor. This will protect both the hand shower and your decor from accidental damage should the hand shower be droppped while in use.
Installation Procedure Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. Shut off main water supply before installation. Tighten the handshower to a shower hose (not included) by hand only. This product requires the installation of certified atmospheric vacuum breaker (AVB) installed in-between the shut off valve and hose inlet. The AVB should be installed so it is vent ports is pointing in other than the upward direction.
Parts List Exploded view G F E D C B A H I J K A B C D E F G H I J K Clip (11294) Non-return Valve (519009) Adaptor (067827-W) O-Ring (072016R) Handle sleeve (108899) O-Ring (004564R) Tube assembly (020958) O-Ring (063056) Flow regulator (112693) Shower head (112695) Teflon tape (203000) 6
Fault Finder Fault Cause Rectification Too low flow. Showerheads clogged. Remove and clean showerheads. May need to replace if clogged. Leaks around the connection between showerhead and shower hose. Gasket is misfitted or damaged. Check for gasket placement.
Safety Tips, Care and Maintenance Safety Tips If you are soldering during faucet installation,remove cartridges, seats, gaskets and washers prior to applying flame, otherwise you will void the warranty. Cover drain openings to avoid losing small parts. When cutting or soldering pipe, use safety glasses to protect your eyes. Important Points Prior to beginning installation. turn off the cold and hot water lines and open the old faucet to release built-up pressure. Overtightening nuts may cause damage.
Guarantee Guarantee of Quality This product is guaranteed against faulty materials and workmanship for 12 months from date of purchase. For the guarantee to be valid, the unit must be installed by a competent person, in accordance with the instruction booklet. Any part found to be defective during the guarantee period, will (at our option) be repaired or replaced, free of charge, provided the unit has been installed, and properly used in accordance with the instruction booklet.
718-302-5292 www.lefroybrooks.com LEFROY BROOKS INC, 1828 TROUTMAN STREET, RIDGEWOOD, NY, 11385 TELEPHONE: 718-302-5292. FAX: 718-302-4177 The use of trademarks, product design and artwork is subject to licence or agreement with Christo A. Lefroy Brooks. The design registrations, trademark registrations and copyrights are protected by law and the use or reproduction outside the terms of an agreement is prohibited. The right to modify designs and dimensions is reserved.